Return to Section TOC

Return to Master TOC

F-37

 

 

 

F-37

 

 

 

TROUBLESHOOTING & REPAIR

 

 

 

AUXILIARY TRANSFORMER NO.1 TEST (continued)

 

 

 

 

TABLE F.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEAD IDENTIFICATION

 

 

 

NORMAL EXPECTED VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM 2 (31) TO 115V (532)

 

 

 

 

 

 

 

 

 

 

115 VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42 TO COM 1A (quick connects)

 

 

 

 

 

 

 

 

 

 

42 VAC

 

 

 

 

 

 

 

 

 

 

 

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

7.Carefully apply the correct input voltage to the POWER WAVE 355/405 and check for the cor- rect secondary voltages per table F.5. Make sure the reconnect jumper lead and switch are configured correctly for the input voltage being applied. Make sure circuit breaker (CB3) is functioning properly.

NOTE: The secondary voltages will vary if the input line voltage varies.

8.If the correct secondary voltages are present, the auxiliary transformer is functioning proper- ly. If any of the secondary voltages are miss- ing or low, check to make certain the primary is configured correctly for the input voltage applied. See Wiring Diagram.

WARNING

High voltage is present at primary of Auxiliary Transformer.

9.If the correct input voltage is applied to the primary, and the secondary voltage(s) are not correct, the auxiliary transformer may be faulty.

10.Remove the input power to the POWER WAVE 355/405.

11.Install the case wraparound cover using a 5/16” nut driver.

Return to Section TOC

Return to Master TOC

POWER WAVE 355/405

Page 79
Image 79
Lincoln Electric SVM159-A service manual Auxiliary Transformer NO.1 Test, Normal Expected Voltage