INSTALLATION
SYSTEM SET-UP
Basic Rules
•Each group is required to have one user interface. No group may have more than one user interface.
•Each group can have up to seven Feed Heads. Exception: Group 3 is limited to a maximum of six Feed Heads.
•Each system has only one power source. For network purposes, the PS belongs to Group 3, which is why group 3 is only allowed 6 feed heads in addition it’s user interface.
•No two feed heads can have identical Group and Feed Head numbers.
•Group and Feed Head ID numbers must be set on the appropriate dip switches at each node. Consult the
•Feed head “0” not allowed.Exception: Simple sys- tem ignores all ID numbers, therefore “FH0” will func- tion.
•Each node must be connected to the
Simple System | FIGURE A.2 |
Group and Feed Head ID numbers are ignored in a simple system.