POWER WAVE 355/405 – Semi-Automatic Operation

Semi Automatic Power Waves can only be used with Linc-Net compatible Power Feed semi-automatic wire feeders. In addition, the Power Feed semi-automatic wire feeders may require optional equipment to access certain weld modes in the Power Wave. Other models of Lincoln feeders, or any models of non-Lincoln wire feeders, cannot be used.

All welding programs and procedures are selected through the Power Feed semi-automatic user interface

REQUIRED EQUIPMENT

Any Linc-Net compatible semi-automatic wire feeding equipment. Specifically, the semi-automatic Power Feed family (PF-10, PF-10X2, PF-11).

LIMITATIONS

Only Linc-Net compatible Power Feed semi-automat- ic wire feeders and users interfaces may be used. Other Lincoln wire feeders or non-Lincoln wire feed- ers cannot be used.

POWER WAVE 355/405 Output Limitations

The POWER WAVE 355/405 will support maximum average output current of 350 Amps @ 60% duty cycle.

DUTY CYCLE AND TIME PERIOD

The duty cycle is based upon a ten minute period. A 60% duty cycle represents 6 minutes of welding and 4 minutes of idling in a ten minute period.

CASE FRONT CONTROLS

All operator controls and adjustments are located on the case front of the Power Wave. (See Figure B.1)

1.POWER SWITCH: Controls input power to the Power Wave.

2.STATUS LIGHT: A two color light that indicates sys- tem errors. Normal operation is a steady green light. Error conditions are indicated, per table B.1.

NOTE: The POWER WAVE 355/405 status light will flash green, and sometimes red and green, for up to one minute when the machine is first turned on. This is a normal situation as the machine goes through a self test at power up.

 

TABLE B.1

 

 

Light

Meaning

Condition

 

Steady Green

System OK. Power source communicating normal-

 

ly with wire feeder and its components.

 

 

Blinking

Occurs during a reset, and indicates the

Green

POWER WAVE 355/405 is mapping (identi-

 

fying) each component in the system.

 

Normal for first 1-10 seconds after power is

 

turned on, or if the system configuration is

 

changed during operation

 

 

A l t e r n a t i n g

Non-recoverable system fault. If the PW

Green and

Status light is flashing any combination of

Red

red and green, errors are present in the

 

POWER WAVE 355/405. Read the error

 

code before the machine is turned off.

 

Error Code interpretation through the Status

 

light is detailed in the LED Status Chart.

 

Individual code digits are flashed in red with

 

a long pause between digits. If more than

 

one code is present, the codes will be sepa-

 

rated by a green light.

 

To clear the error, turn power source off, and

 

back on to reset.

 

 

Steady Red

Non recoverable hardware fault. Generally

 

indicates nothing is connected to the

 

POWER WAVE 355/405 wire feeder recep-

 

tacle. See Trouble Shooting Section.

 

 

Blinking Red

Not applicable.

 

 

3.HIGH TEMPERATURE LIGHT (thermal overload): A yellow light that comes on when an over temper- ature situation occurs. Output is disabled and the fan continues to run, until the machine cools down. When cool, the light goes out and output is enabled.

4.CB1 WIRE FEEDER CIRCUIT BREAKER: Protects 40 volt DC wire feeder power supply.