Faults and trouble shooting

Faults and trouble shooting

When either one of the variable speed drives or frequen- cy converters in the machine experience a fault and “trip” out, they will cease to run and an error message will ap- pear flashing on the keypad display (see picture below).

The following list are the most commonly experienced faults and possible action steps.

Fault code

Fault Code

Possible Cause

Action

1—OVERCURRENT

Motor being worked too hard and

Check current being drawn when machine is

 

drawing extra current.

running. Reduce speed setting and current draw

 

 

back into acceptable limits as described on

 

 

previous page.

 

Short circuit on output side of vari-

Check wiring in plugs connected to motor cables

 

able speed drives or frequency con-

or inside connection boxes on motors.

 

verters.

 

 

Motor failure (very rare)

Have motor tested and replace if required.

3—EARTH FAULT

Short circuit on output side of vari-

Check wiring in plugs connected to motor cables

 

able speed drives or frequency con-

or inside connection boxes on motors.

 

verters.

 

 

Motor failure (very rare)

Have motor tested and replace if required.

9—UNDERVOLTAGE

Insufficient voltage supply to ma-

Check power supply and ensure correct voltage.

 

chine.

 

 

Power supply to variable speed

Re-connect power to grinder.

 

drives or frequency converters has

 

 

been turned off.

 

11—OUTPUT PHASE

Short circuit on output side of vari-

Check wiring in plugs connected to motor cables

SUPERVISION

able speed drives or frequency con-

or inside connection boxes on motors.

 

verters.

 

 

Motor failure (very rare)

Have motor tested and replace if required.

14—UNIT OVER TEM-

Variable speed drives or frequency

Open door on electrical cabinet to increase ven-

PERATURE

converter over temperature due to

tilation.Have variable speed drives or frequency

 

high temperature working environ-

converter tested by service agent.

 

ment or faulty temperature sensor.

 

 

 

 

15—MOTOR STALLED

Motor being worked too hard and

Check current being drawn when machine is

 

drawing extra current.

running. Reduce speed setting and current draw

 

 

back into acceptable limits as described on

 

 

previous page.

 

Mechanical jam preventing motor

Try rotating grinding discs and planetary head by

 

from turning.

hand to see if jam exists

16 - MOTOR OVERTEM-

Motor being worked too hard and

Check current being drawn when machine is

PERATURE

drawing extra current.

running. Reduce speed setting and current draw

 

 

back into acceptable limits as described on

 

 

previous page.

16 - English

Page 14
Image 14
Husqvarna PG820, PG680 manuel dutilisation Faults and trouble shooting, Fault Code Possible Cause Action