ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Elctrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

SERVICE

PHASE

WIRE

APPROX.

FUSING

CIRCUIT

AMP DRAW

Dual Element

VOLTAGE

SERVICE

BREAKER

 

 

 

Time Delay

 

 

 

60 Hz

50 Hz

 

 

 

 

 

 

120

2

8.7

---

15

15

 

 

 

 

 

 

 

7/21/03

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the upper left side panel area behind the top control (access) door.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation.