Input Interrupts

Section 7-3

Clearing Recorded Interrupts

The EI(694) instruction does not enable all interrupts. If an interrupt was masked before all interrupts were disabled, that interrupt will still be masked after the prohibition on all interrupts is cleared.

The CLI(691) instruction clears the interrupt event information recorded while all interrupts were disabled by the DI(802) instruction.

7-3

Input Interrupts

 

7-3-1

Applicable Models

 

 

 

 

 

 

 

Model number

Functions

 

 

 

 

 

 

FQM1-MMP21

Motion Control Module for Pulse I/O

 

 

 

 

 

 

FQM1-MMA21

Motion Control Module for Analog I/O

 

 

 

 

7-3-2

Overview of the Input Interrupt Function

 

 

Contact inputs 0 to 3 in the Motion Control Modules can be used for external

 

 

interrupt inputs. These inputs correspond to CIO 0000.00 to CIO 0000.03.

 

 

The interrupt tasks corresponding to these inputs are fixed and cannot be

 

 

changed. Contact inputs 0 to 3 call interrupt tasks 000 to 003, respectively.

 

Note If the input interrupts are not being used, interrupt tasks 000 to 003 can be

 

 

used as interrupt tasks for other interrupt functions.

7-3-3

Interrupt Modes

 

There are two modes that can be used for the input interrupts. Each of the four interrupt inputs can be set to either of these modes.

Input Interrupt Mode:

An interrupt is generated when the external input turns ON, OFF, or both.

Counter Mode:

External signals are counted, decrementing the PV from an SV, and an interrupt is generated when the PV equals 0.

The interrupt mode for each interrupt input is set using the MSKS(690) instruction.

7-3-4 Input Interrupt Specifications

Input Interrupt Mode

Item

Specification

 

 

Interrupt condition

Contact inputs 0 to 3 (CIO 0000.00 to CIO 0000.03) turn ON,

 

OFF, or both

 

Note Set the interrupt condition in the System Setup.

 

 

Interrupt task num-

CIO 0000.00 to CIO 0000.03: Interrupt tasks 000 to 003

bers

 

 

 

Response time

0.1 ms for ON interrupt condition

 

The response time is measured from when interrupt condition

 

is met until interrupt task execution starts.

 

 

Signal pulse width

ON: 0.1 ms min., OFF: 0.2 ms min.

 

 