Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 Section, A606, Note Refer to 7-7-6Absolute Present Value

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 229
Image 229
A606

Functions for Servo Drivers Compatible with Absolute Encoders

Section 7-7

 

 

 

 

 

 

 

 

 

Word

Bits

 

Function

 

 

Details

 

Controlled

 

 

 

 

 

 

 

 

by

 

 

 

 

 

 

 

A606

00 to 15

High-speed

Counter

Absolute

The same as for high-speed counter 1, except

Motion Con-

and

 

Counter 2

operation

No. of

that the high-speed counter frequency mea-

 

trol Module

A607

 

 

• Absolute

rotations

surement cannot be performed.

 

 

 

 

 

PV

 

 

 

 

 

 

 

linear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CW)

 

 

 

 

 

 

 

 

• Absolute

 

 

 

 

 

 

 

 

circular

 

 

 

 

 

 

 

 

• Absolute

 

 

 

 

 

 

 

 

linear

 

 

 

 

 

 

 

 

(CW+)

 

 

 

 

 

 

 

 

 

 

 

 

 

A608

04

High-speed

Absolute No. of Rota-

OFF: No error

 

Motion Con-

 

 

Counter 1

tions Read Error Flag

ON:

Error occurred

 

trol Module

 

 

Status

 

 

 

 

 

 

 

05

Absolute No. of Rota-

OFF: Not reading or reading

 

 

 

 

 

 

 

 

 

tions Read Completed

ON: Reading completed (This is set at the

 

 

 

 

 

Flag

 

 

 

 

 

 

 

 

completion of receiving serial data on No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of rotations.)

 

 

 

 

 

 

 

 

 

 

12

 

Absolute Offset Preset

An error occurred when storing the absolute

 

 

 

 

 

Error Flag

 

offset in the System Setup parameter area.

 

 

 

 

 

 

 

 

 

A609

04

High-speed

Absolute No. of rota-

These flags have the same functions as the

 

Motion Con-

 

 

Counter 2

tions read error

ones for High-speed Counter 1 Status, above.

trol Module

 

 

Status

 

 

 

 

 

 

 

05

Absolute No. of rota-

 

 

 

 

 

 

 

 

 

 

 

 

 

tions read completed

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

Absolute offset preset

 

 

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

 

 

A610

05

High-speed

Absolute offset preset

OFF:

No preset

 

Motion Con-

 

 

Counter 1

 

 

OFF to ON: Offset obtained from multi-turn

 

trol Module

 

 

Command

 

 

 

 

 

 

 

 

 

data from Servo Driver and the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. of initial incremental pulses

 

 

 

 

 

 

 

 

are stored as the absolute offset.

 

 

 

 

 

 

 

When defining machine origin, dif-

 

 

 

 

 

 

 

ference between machine and

 

 

 

 

 

 

 

 

encoder's origins is preset as the

 

 

 

 

 

 

 

absolute offset.

 

 

 

 

 

 

 

 

 

 

 

06

 

Absolute PV preset

OFF:

Absolute PV preset invalid

 

 

 

 

 

 

 

OFF to ON: At this point, the absolute PV is

 

 

 

 

 

 

 

 

stored in high-speed counter PV 1

 

 

 

 

 

 

 

(A600 and A601).

 

 

 

 

 

 

 

Note Refer to 7-7-6 Absolute Present Value

 

 

 

 

 

 

 

 

for details on the absolute PV.

 

 

 

 

 

 

 

 

 

 

 

07

 

Absolute No. of rota-

OFF:

No. of rotations data read from

 

 

 

 

 

tions read

 

 

Servo Driver invalid

 

 

 

 

 

 

 

ON:

At the rising edge of the signal,

 

 

 

 

 

 

 

 

SEN is output to Servo Driver, and

 

 

 

 

 

 

 

multi-turn data is received from

 

 

 

 

 

 

 

 

the phase A input.

 

 

 

 

 

 

 

 

A611

05

High-speed

Absolute Offset Preset

These control bits have the same functions as

Motion Con-

 

 

Counter 2

 

 

the ones for High-speed Counter 1 Command,

trol Module

 

06

Absolute PV Preset

 

Command

above.

 

 

 

 

 

 

 

 

 

07

Absolute No. of Rota-

 

 

 

 

 

 

 

 

 

 

 

tions Read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

206

Page 229
Image 229
Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 operation manual Section, A606, Note Refer to 7-7-6Absolute Present Value