Omron FQM1-MMP21, FQM1-CM001, FQM1-MMA21 Auxiliary Area Allocations, Appendix D, A414

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 374
Image 374
Manual background

Auxiliary Area Allocations

Appendix D

 

 

 

 

 

Address

Bits

 

Name

Function

 

 

 

 

 

A414

02

RS-422A

Parity Error Flag

These error flags turn ON when an error has occurred at the RS-

 

 

Port

 

422A port.

 

03

Framing Error Flag

 

Error

 

 

 

 

 

 

04

Flags

Overrun Error Flag

 

 

 

 

 

 

 

05

 

Timeout Error Flag

 

 

 

 

 

 

 

08

RS-422A Port Communications Error Flag

Turns ON when a communications error has occurred at the RS-

 

 

 

 

422A port.

 

 

 

 

 

09

RS-422A Port Send Ready Flag (no-protocol

Turns ON when the RS-422A port is ready to send data in no-pro-

 

 

mode)

 

tocol mode.

 

10

RS-422A Port Reception Completed Flag (no-

Turns ON when the RS-422A port has completed the reception in

 

 

protocol mode)

no-protocol mode.

 

 

 

 

 

11

RS-422A Port Reception Overflow Flag (no-pro-

Turns ON when a data overflow occurred during reception

 

 

tocol mode)

through the RS-422A port in no-protocol mode.

 

 

 

 

 

15

RS-422A Port Settings Changing Flag

Turns ON while the RS-422A port’s communications settings are

 

 

 

 

being changed.

A415

00 to 15

RS-422A Port Reception Counter (no-protocol

Indicates (in binary) the number of bytes of data received when

 

 

mode)

 

the RS-422A port is in no-protocol mode.

 

 

 

 

A500

14

Error Log Pointer Reset and Memory Not Held

The error log pointer in A408 is reset to 0000 hex and Memory

 

 

Flag OFF Bit

Not Held Flag (A404.14) is turned OFF when this bit is turned

 

 

 

 

ON.

 

 

 

 

A502

00

RS-232C Port Restart Bit

Turn this bit ON to restart the RS-232C port.

 

 

 

 

This bit is turned OFF automatically when the restart processing

 

 

 

 

is completed.

 

 

 

 

 

01

Peripheral Port Restart Bit

Turn this bit ON to restart the peripheral port.

 

 

 

 

This bit is turned OFF automatically when the restart processing

 

 

 

 

is completed.

 

 

 

 

 

02

RS-422A Port Restart Bit

Turn this bit ON to restart the RS-422A port.

 

 

 

 

This bit is turned OFF automatically when the restart processing

 

 

 

 

is completed.

 

 

 

 

A507

00 to 15

Data Trace Period

Data will be traced using the period specified here when tracing

 

 

 

 

each cycle is specified from the CX-Programmer.

 

 

 

 

0000 hex: Each cycle

 

 

 

 

0001 to 000F hex: Every 2 to 16 cycles

 

 

 

 

A508

09

Differentiate Monitor Completed Flag

Turns ON when the differentiate monitor condition has been

 

 

 

 

established during execution of differentiation monitoring.

 

 

 

 

(This flag will be turned OFF when differentiation monitoring

 

 

 

 

starts.)

 

11

Trace Trigger Monitor Flag

Turns ON when a trigger condition is established by the Trace

 

 

 

 

Start Bit (A508.14). OFF when the next Data Trace is started by

 

 

 

 

the Sampling Start bit (A508.15).

 

12

Trace Completed Flag

Turns ON when sampling of a region of trace memory has been

 

 

 

 

completed during execution of a Trace.

 

 

 

 

Turns OFF when the next time the Sampling Start Bit (A508.15) is

 

 

 

 

turned from OFF to ON.

 

 

 

 

 

13

Trace Busy Flag

Turns ON when the Sampling Start Bit (A508.15) is turned from

 

 

 

 

OFF to ON. Turns OFF when the trace is completed.

 

14

Trace Start Bit

Turn this bit ON to establish the trigger condition. The offset indi-

 

 

 

 

cated by the delay value (positive or negative) determines which

 

 

 

 

data samples are valid.

 

15

Sampling Start Bit

When a data trace is started by turning this bit from OFF to ON

 

 

 

 

from the CX-Programmer, the FQM1 will begin storing data in

 

 

 

 

Trace Memory by one of the three following methods:

 

 

 

 

1) Data is sampled at regular intervals (10 to 2,550 ms).

 

 

 

 

2) Data is sampled when TRSM(045) is executed in the program.

 

 

 

 

3) Data is sampled at the end of every cycle.

 

 

 

 

The operation of A508.15 can be controlled only from the CX-Pro-

 

 

 

 

grammer.

 

 

 

 

A509

15

Constant Cycle Time Exceeded Error Clear Bit

Used to enable the constant cycle time function again after the

 

 

 

 

constant cycle time has been exceeded.

 

 

 

 

A510 to

00 to 15

Macro Area Input Words

Before the subroutine specified in MCRO(099) is executed, the

A514

 

 

 

contents of the five words specified in the operand to be passed

 

 

 

 

to the subroutine are stored here.

 

 

 

 

A515 to

00 to 15

Macro Area Output Words

After the subroutine specified in MCRO(099) has been executed,

A519

 

 

 

the results of the subroutine are transferred to these five words.

351

Page 374
Image 374
Omron FQM1-MMP21, FQM1-CM001, FQM1-MMA21 operation manual Auxiliary Area Allocations, Appendix D, A414