Conformance to EC Directives

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit

 

 

 

Current

Characteristic

Required element

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diode method

 

 

 

No

Yes

The diode connected in parallel with

The reversed dielectric strength value

 

 

 

 

 

the load changes energy accumulated

of the diode must be at least 10 times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

by the coil into a current, which then

as large as the circuit voltage value.

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Inductive load

 

 

resistance of the inductive load.

current.

 

 

 

 

 

 

 

 

 

 

 

 

flows into the coil so that the current

The forward current of the diode must

 

 

 

 

 

 

 

 

 

 

 

 

will be converted into Joule heat by the

be the same as or larger than the load

 

supply

 

 

 

 

 

 

This time lag, between the moment the

The reversed dielectric strength value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit is opened and the moment the

of the diode may be two to three times

 

 

 

 

 

 

 

 

 

 

 

 

load is reset, caused by this method is

larger than the supply voltage if the

 

 

 

 

 

 

 

 

 

 

 

 

longer than that caused by the CR

surge protector is applied to electronic

 

 

 

 

 

 

 

 

 

 

 

 

method.

circuits with low circuit voltages.

Varistor method

Yes

Yes

The varistor method prevents the impo-

---

 

 

sition of high voltage between the con-

 

 

 

 

 

 

 

 

tacts by using the constant voltage

 

Power

Inductive load

 

characteristic of the varistor. There is

 

 

time lag between the moment the cir-

 

 

 

 

 

 

 

 

cuit is opened and the moment the load

 

supply

 

 

is reset.

 

 

 

 

 

If the supply voltage is 24 or 48 V, insert the varistor in parallel with the load. If the supply voltage is 100 to 200 V, insert the varistor between the contacts.

When switching a load with a high inrush current such as an incandescent lamp, suppress the inrush current as shown below.

Countermeasure 1

Countermeasure 2

 

R

OUT

OUT

R

 

COM

COM

Providing a dark current of approx.

Providing a limiting resistor

one-third of the rated value

 

through an incandescent lamp

 

The following Unit and Cables can be used with the FQM1-series Flexible

Motion Controller.

Name

Model

Cable length

Relay Unit

XW2B-80J7-1A

---

Controller Connect-

XW2Z-050J-A28

0.5 m

ing Cables

XW2Z-100J-A28

1 m

 

 

XW2Z-050J-A30

0.5 m

 

XW2Z-100J-A30

1 m

 

XW2Z-050J-A31

0.5 m

 

XW2Z-100J-A31

1 m

xxi

Page 20
Image 20
Omron FQM1-MMP21, FQM1-CM001, FQM1-MMA21 Circuit Current Characteristic Required element, Name Model Cable length