System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

 

 

 

 

 

 

 

Address

Bits

Name

Function

 

Controlled

 

 

 

 

 

 

by

A608

00

High-speed

Target Compar-

OFF: Target value comparison is not being performed for

 

Module

 

 

counter 1 status

ison In-

CTBL(882).

 

 

 

 

 

progress Flag

Note This flag is always OFF for range comparison.

 

 

 

 

 

 

 

 

 

 

 

 

ON: Target value comparison is being performed for CTBL(882).

 

 

 

 

 

Note Target comparison is continued without interruption once it

 

 

 

 

 

has been started (as opposed to range comparison), so this flag

 

 

 

 

 

can be used to check whether target comparison is in progress.

 

 

 

 

 

 

 

 

01

 

PV Overflow/

OFF: There is no counter overflow or underflow in Linear Counter

 

 

 

 

Underflow Flag

Mode. This flag will always be OFF in Circular Counter Mode.

 

 

 

 

 

 

ON: There is a counter overflow or underflow in Linear Counter

 

 

 

 

 

 

Mode. The counter PV will be fixed at the overflow or underflow

 

 

 

 

 

 

limit. This flag will be cleared when the High-speed Counter Start

 

 

 

 

 

Bit is turned OFF.

 

 

 

 

 

 

 

 

 

 

02

 

Reserved

---

 

 

 

 

 

 

 

 

 

 

03

 

Phase Z Input

ON for one cycle when the counter PV is reset with the counter

 

 

 

 

 

Reset Flag (ON

reset method set to a phase Z + software reset.

 

 

 

 

 

for one cycle)

Note This flag will turn ON for one cycle after the counter PV is

 

 

 

 

 

 

 

 

 

 

reset if the phase Z signal (reset input) turns ON while the High-

 

 

 

 

 

speed Counter Reset Bit (A610.01) is ON.

 

 

 

 

 

 

 

 

 

 

04

 

Absolute No. of

OFF: No error

 

 

 

 

 

Rotations Read

ON: Error

 

 

 

 

 

Error Flag

 

 

 

 

05

 

Absolute No. of

OFF: Rotations being read or reading has not been executed.

 

 

 

 

 

Rotations Read

ON: Reading has been completed (Turned ON when serial recep-

 

 

 

 

Completed

tion of the number of rotations has been completed.)

 

 

 

 

 

Flag

 

 

 

 

06

 

Measuring Flag

OFF: Changes in the counter PV or the counter frequency is not

 

 

 

 

(measurement

being measured.

 

 

 

 

 

mode 1 or 2)

ON: Changes in the counter PV or the counter frequency is being

 

 

 

 

 

measured.

 

 

 

 

 

 

In measurement mode 1, this flag will turn ON at the beginning of

 

 

 

 

 

the sampling time after the Measurement Start Bit (A610.02) is

 

 

 

 

 

 

turned ON.

 

 

 

 

 

 

Note Valid when Counter Data Display in System Setup is set to

 

 

 

 

 

Counter Movements (mode 1) or Frequency (mode 2).

 

 

 

 

 

 

 

 

 

 

07

 

High-speed

OFF: Counter is not operating.

 

 

 

 

 

Counter Oper-

ON: Counter is operating.

 

 

 

 

 

ating Flag

 

 

 

 

08

 

Count Latched

OFF: Count has not been latched.

 

 

 

 

 

Flag

ON: Latching the count has been completed for the latch input.

 

 

 

 

 

 

 

 

 

 

09 to 11

 

Reserved

---

 

 

 

 

 

 

 

 

 

 

12

 

Absolute Off-

OFF: No error occurred when saving the absolute offset.

 

 

 

 

 

set Preset

ON: An error occurred when saving the absolute offset.

 

 

 

 

 

Error Flag

 

 

 

 

13 to 15

 

Reserved

---

 

 

 

 

 

 

 

 

 

340