A620 to

System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

 

 

 

 

 

 

 

Address

Bits

Name

Function

 

Controlled

 

 

 

 

 

 

 

by

A620 to

00 to 15

Pulse Output 1 PV

Contains the pulse output PV as an 8-digit hexadecimal number.

Module

A621

 

Note This item applies when the

Relative mode: 00000000 to FFFFFFFF hex

 

 

 

 

operation mode is relative pulse

Absolute linear mode: 80000000 to 7FFFFFFF hex

 

 

 

 

output, absolute pulse output in

Absolute circular mode: 00000000 to circular maximum count

 

 

 

 

linear mode, absolute pulse out-

 

 

 

 

put in circular mode, or elec-

 

 

 

 

 

tronic cam mode.

 

 

 

 

 

 

One-shot Pulse Output 1 ON

Contains the time that the one-shot pulse output has been ON as

 

 

 

Time

 

an 8-digit hexadecimal number.

 

 

 

 

Note This item applies when the

0000 0000 to 0000 270F (unit: set by STIM(980))

 

 

 

 

operation mode is one-shot out-

 

 

 

 

 

put mode.

 

 

 

 

 

 

 

 

 

 

 

 

Pulse Time Measurement 1

Contains the time measured by the pulse counter as an 8-digit

 

 

 

 

Note This item applies when the

hexadecimal number.

 

 

 

 

operation mode is time measure-

0000 0000 to FFFF FFFF hex (unit: set by STIM(980))

 

 

 

 

ment mode using a pulse

 

 

 

 

 

counter.

 

 

 

 

 

 

 

 

 

 

A622 to

00 to 15

Pulse Output 2 PV

Same as for Pulse Output 1 PV.

 

 

A623

 

 

 

 

 

 

 

 

One-shot Pulse Output 2 ON

Same as for One-shot Pulse Output 1 ON time.

 

 

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

Pulse Time Measurement 2

Same as for Pulse Time Measurement 1.

 

 

 

 

 

 

 

 

 

A624

00

Pulse Output 1

 

Pulse Output

OFF: Pulse output not completed (OFF during pulse output).

 

 

 

 

Status

 

Completed

ON: Pulse output completed (ON when pulse distribution has been

 

 

 

 

 

Flag

completed).

 

 

 

 

 

 

 

 

 

 

 

01

 

 

Pulse Output

OFF: Pulse output amount not set by PULS(886).

 

 

 

 

 

 

Set Flag

ON: Pulse output amount set by PULS(886).

 

 

 

 

 

 

 

 

 

 

 

02

 

 

Target Fre-

OFF: Target speed has been reached during pulse output for

 

 

 

 

 

 

quency Not

PLS2(887).

 

 

 

 

 

 

Reached Flag

ON: Decelerated before reaching the target speed during pulse

 

 

 

 

 

 

 

output for PLS2(887).

 

 

 

 

 

 

 

 

 

 

 

03

 

 

Target Compar-

OFF: Comparison stopped.

 

 

 

 

 

 

ison Flag

ON: Comparison in progress.

 

 

 

 

 

 

 

 

 

 

 

04

 

 

Independent

OFF: Pulses not being output or being output continuously.

 

 

 

 

 

 

Pulse Output

ON: Pulses being output.

 

 

 

 

 

 

Flag

 

 

 

 

05

 

 

PLS2 Position-

OFF: Not positioning.

 

 

 

 

 

 

ing Flag

ON: Positioning in progress.

 

 

 

 

 

 

 

 

 

 

 

06

 

 

Accelerating/

OFF: No output or constant-speed output.

 

 

 

 

 

 

Decelerating

ON: Acceleration or deceleration in progress for ACC(888) or

 

 

 

 

 

 

Flag

PLS2(887).

 

 

 

 

 

 

 

 

 

 

 

07

 

 

Pulse Output

OFF: Pulse output stopped.

 

 

 

 

 

 

Flag

ON: Pulse output in progress.

 

 

 

 

 

 

 

 

 

 

 

08 to 15

 

 

Reserved

---

 

 

 

 

 

 

 

 

 

 

A625

00

Pulse Output 2

 

Pulse Output

Same as for Pulse Output 1 Status.

 

 

 

 

Status

 

Completed

 

 

 

 

 

 

 

Flag

 

 

 

 

 

 

 

 

 

 

 

 

01

 

 

Pulse Output

 

 

 

 

 

 

 

Set Flag

 

 

 

 

02

 

 

Target Fre-

 

 

 

 

 

 

 

quency Not

 

 

 

 

 

 

 

Reached Flag

 

 

 

 

03

 

 

Target Compar-

 

 

 

 

 

 

 

ison Flag

 

 

 

 

 

 

 

 

 

 

 

 

04

 

 

Independent

 

 

 

 

 

 

 

Pulse Output

 

 

 

 

 

 

 

Flag

 

 

 

 

 

 

 

 

 

 

 

 

05

 

 

PLS2 Position-

 

 

 

 

 

 

 

ing Flag

 

 

 

 

 

 

 

 

 

 

 

 

06

 

 

Accelerating/

 

 

 

 

 

 

 

Decelerating

 

 

 

 

 

 

 

Flag

 

 

 

 

 

 

 

 

 

 

 

 

07

 

 

Pulse Output

 

 

 

 

 

 

 

Flag

 

 

 

 

08 to 15

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

334