Pulse OutputsSection 7-6

Pulse OutputsSection 7-6

7-6

Pulse Outputs

 

 

 

7-6-1

Applicable Models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Functions

 

 

 

 

 

 

 

 

 

 

 

 

FQM1-MMP21

 

Motion Control Module with Pulse I/O

7-6-2

Outline

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The FQM1-MMP21 Motion Control Module provides 2 pulse outputs. The

 

 

 

pulse outputs can be used for the following functions.

 

 

Note

Set the pulse output operation mode for each output in System Setup (Pulse

 

 

 

Output Tab Page).

 

 

 

 

 

 

 

 

 

Function

 

 

Description

 

Processing for PV

 

 

 

 

 

Pulse output opera-

The pulse outputs can be used for positioning or speed control at

It is possible to generate tar-

tion mode

 

a fixed duty ratio. Select one of five pulse output operation

get-value interrupts (see note 2)

 

 

modes: Relative pulse output, linear absolute pulse output, circu-

or range-comparison bit pattern

 

 

lar absolute pulse output, electronic cam (linear), and electronic

outputs based on the pulse out-

 

 

cam (circular).

 

 

put’s PV. (See note 1.)

 

 

 

 

 

One-shot pulse out-

Pulse output turned ON for only the specified interval (0.01 to

None

puts

 

9,999 ms.)

 

 

 

 

 

 

 

 

 

 

 

Calculation (time

Enables use of the pulse output counter as a timer using the

It is possible to generate tar-

measurement)

one-shot pulse output timer.

 

 

get-value interrupts or

 

 

Note Pulses are not output for this mode and the specified port

range-comparison bit pattern

 

 

outputs based on the pulse

 

 

cannot be used for pulse output.

 

 

 

 

counter’s PV. (See note 1.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

(1) The processes listed in the following table can be performed for the PV of

 

 

 

a pulse output, pulse output counter timer, or one-shot pulse output

 

 

 

elapsed time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process

 

 

Description

 

 

 

 

 

 

 

 

 

 

Target value interrupts

An interrupt task can be executed when the

 

 

 

 

 

 

 

high-speed counter PV equals a target value.

 

 

 

 

 

 

 

 

 

 

Bit pattern outputs for

A user-set bit pattern is output internally when the

 

 

 

 

range comparisons

high-speed counter PV is within a specified range.

 

 

 

 

 

 

 

 

 

(2) Cannot be combined with pulse output in independent mode.