Appendix C

System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Sync Cycle Time

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+319

00 to 14

0000 hex: Default (Coordina-

Sets the cycle time for the Coordinator

A404.06 (Sync Cycle

At power ON

 

 

tor Module cycle time)

Module when high-speed synced oper-

Time Too Long Flag)

 

 

 

0001 to 0064 hex: 0.1 to 10.0

ation is to be used only between Motion

 

 

 

 

ms (unit: 0.1 ms)

Control Modules.

 

 

 

 

Default: Coordinator Module

 

 

 

 

 

cycle time

 

 

 

 

 

 

 

 

 

Sync Mode

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

+319

15

0: Sync mode

Sets either Sync Mode or Async Mode.

---

At power ON

 

 

1: Async mode

Sync Mode is used to sync operation

 

 

 

 

Default: Sync mode

between the Coordinator Module and

 

 

 

 

Motion Control Modules.

 

 

 

 

 

 

 

 

 

 

Async Mode is convenient for debug-

 

 

 

 

 

ging Motion Control Modules even if

 

 

 

 

 

Sync Mode is to be used for actual

 

 

 

 

 

operation.

 

 

Startup Mode Setting (CX-Programmer: Startup Tab Page)

 

Startup Mode

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+81

00 to 11

00 hex: PROGRAM mode

Sets the mode in which the Coordinator

---

At power ON

 

 

01 hex: MONITOR mode

Module will start. The mode set here

 

 

 

 

02 hex: RUN mode

can also be enabled and disabled. If

 

 

 

 

this setting is disabled, the Coordinator

 

 

 

 

 

 

 

 

15

00: Setting disabled

Module will start in RUN mode.

 

 

 

 

01: Setting enabled

 

 

 

 

 

Default: Setting disabled

 

 

 

 

 

 

 

 

 

Cycle Time Settings (CX-Programmer: Timer/Peripheral Service)

 

Cycle Time

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+307

00 to 15

0001 to 03E8 hex: 0.1 to

Set to 0001 to 03E8 hex to specify a

A404.05 (Constant

At start of opera-

 

 

100.0 ms (unit: 0.1 ms)

constant (minimum) cycle time. If the

Cycle Time Exceeded

tion (cannot be

 

 

Default: 0000 hex (variable

cycle time is less than this setting, it will

Flag)

changed during

 

 

cycle time)

be extended until this time passes.

 

operation)

 

 

 

Leave this setting at 0000 for a variable

 

 

 

 

 

cycle time.

 

 

 

 

 

 

 

 

Watch Cycle Time

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

+308

00 to 15

0001 to 0064 hex: 1 to 100

Change this setting only when you want

A208 to A209 (Present

At start of opera-

 

 

ms (unit: 0.1 ms)

to change the default maximum cycle

Cycle Time)

tion (cannot be

 

 

Default: 0000 hex (50 ms)

time. The Cycle Time Too Long Flag

 

changed during

 

 

 

(A401.08) will be turned ON if the

 

operation)

 

 

 

actual cycle time exceeds this setting.

 

 

312