System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Sync Cycle Time

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+319

00 to 14

0000 hex: Default (Coordina-

Sets the cycle time for the Coordinator

A404.06 (Sync Cycle

At power ON

 

 

tor Module cycle time)

Module when high-speed synced oper-

Time Too Long Flag)

 

 

 

0001 to 0064 hex: 0.1 to 10.0

ation is to be used only between Motion

 

 

 

 

ms (unit: 0.1 ms)

Control Modules.

 

 

 

 

Default: Coordinator Module

 

 

 

 

 

cycle time

 

 

 

 

 

 

 

 

 

Sync Mode

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

+319

15

0: Sync mode

Sets either Sync Mode or Async Mode.

---

At power ON

 

 

1: Async mode

Sync Mode is used to sync operation

 

 

 

 

Default: Sync mode

between the Coordinator Module and

 

 

 

 

Motion Control Modules.

 

 

 

 

 

 

 

 

 

 

Async Mode is convenient for debug-

 

 

 

 

 

ging Motion Control Modules even if

 

 

 

 

 

Sync Mode is to be used for actual

 

 

 

 

 

operation.

 

 

Startup Mode Setting (CX-Programmer: Startup Tab Page)

 

Startup Mode

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+81

00 to 11

00 hex: PROGRAM mode

Sets the mode in which the Coordinator

---

At power ON

 

 

01 hex: MONITOR mode

Module will start. The mode set here

 

 

 

 

02 hex: RUN mode

can also be enabled and disabled. If

 

 

 

 

this setting is disabled, the Coordinator

 

 

 

 

 

 

 

 

15

00: Setting disabled

Module will start in RUN mode.

 

 

 

 

01: Setting enabled

 

 

 

 

 

Default: Setting disabled

 

 

 

 

 

 

 

 

 

Cycle Time Settings (CX-Programmer: Timer/Peripheral Service)

 

Cycle Time

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+307

00 to 15

0001 to 03E8 hex: 0.1 to

Set to 0001 to 03E8 hex to specify a

A404.05 (Constant

At start of opera-

 

 

100.0 ms (unit: 0.1 ms)

constant (minimum) cycle time. If the

Cycle Time Exceeded

tion (cannot be

 

 

Default: 0000 hex (variable

cycle time is less than this setting, it will

Flag)

changed during

 

 

cycle time)

be extended until this time passes.

 

operation)

 

 

 

Leave this setting at 0000 for a variable

 

 

 

 

 

cycle time.

 

 

 

 

 

 

 

 

Watch Cycle Time

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

+308

00 to 15

0001 to 0064 hex: 1 to 100

Change this setting only when you want

A208 to A209 (Present

At start of opera-

 

 

ms (unit: 0.1 ms)

to change the default maximum cycle

Cycle Time)

tion (cannot be

 

 

Default: 0000 hex (50 ms)

time. The Cycle Time Too Long Flag

 

changed during

 

 

 

(A401.08) will be turned ON if the

 

operation)

 

 

 

actual cycle time exceeds this setting.

 

 

312

Page 335
Image 335
Omron FQM1-MMP21, FQM1-CM001, FQM1-MMA21 operation manual Appendix C, Startup Mode Setting CX-Programmer Startup Tab