Omron FQM1-MMA21 Appendix C, Baud Rate, Serial Communications Mode, Data Format, Send Delay

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 340
Image 340
Data Format

System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Baud Rate

 

 

 

 

 

 

 

 

 

 

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+161

00 to 07

00 hex: 9,600

Only settings 00 hex and 06 to 09 hex

A410.15 (RS-232C Port

At next cycle (Also

 

 

06 hex: 9,600

can be used in peripheral bus mode.

Settings Changing Flag)

can be changed

 

 

07 hex: 19,200

 

 

with STUP (237).)

 

 

 

 

 

 

 

08 hex: 38,400

 

 

 

 

 

09 hex: 57,600

 

 

 

 

 

Unit: bit/s

 

 

 

 

 

Default: 00 hex

 

 

 

 

 

 

 

 

 

RS-232 Port Settings for No-protocol Communications (RS-232C)

Serial Communications Mode

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

+160

08 to 11

03 hex: No-protocol

This setting determines whether the

A410.15 (RS-232C Port

At next cycle (Also

 

 

Default: 00 hex

RS-232C port will operate in No-proto-

Settings Changing Flag)

can be changed

 

 

 

col mode or another serial communica-

 

with STUP (237).)

 

 

 

tions mode. Set 03 for No-protocol

 

 

 

 

 

Mode.

 

 

Data Format

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+160

15

0: Default format

The standard settings are for 1 start bit,

A410.15 (RS-232C Port

At next cycle (Also

 

 

1: Custom

7-bit data, even parity, 2 stop bits, and

Settings Changing Flag)

can be changed

 

 

Default: 00 hex

9,600 baud.

 

with STUP (237).)

 

 

 

 

 

 

 

 

 

 

 

 

03

0: 7-bit

Sets the data length.

 

 

 

 

1: 8-bit

 

 

 

 

 

Default: 0

 

 

 

 

 

 

 

 

 

 

02

0: 2 bits

Sets the number of stop bits.

 

 

 

 

1: 1 bit

 

 

 

 

 

Default: 0

 

 

 

 

 

 

 

 

 

 

00 and

00: Even

Sets the parity.

 

 

 

01

01: Odd

 

 

 

 

 

10: None

 

 

 

 

 

Default: 00 hex

 

 

 

 

 

 

 

 

 

Baud Rate

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+161

00 to 07

00 hex: 9,600

This setting is valid when the RS-232C

A410.15 (RS-232C Port

At next cycle (Also

 

 

01 hex: 300

port is set for the No-protocol Serial

Settings Changing Flag)

can be changed

 

 

02 hex: 600

Communications Mode. Set the Data

 

with STUP (237).)

 

 

Format setting to 1 to enable this set-

 

 

 

 

03 hex: 1,200

 

 

 

 

ting.

 

 

 

 

04 hex: 2,400

 

 

 

 

 

05 hex: 4,800

 

 

 

 

 

06 hex: 9,600

 

 

 

 

 

07 hex: 19,200

 

 

 

 

 

08 hex: 38,400

 

 

 

 

 

09 hex: 57,600

 

 

 

 

 

Unit: bit/s

 

 

 

 

 

Default: 00 hex

 

 

 

 

 

 

 

 

 

Send Delay

Address

Settings

Function

Related flags and

When setting is

 

 

 

 

words

read

Word

Bits

 

 

 

 

 

 

 

 

 

 

 

 

+162

00 to 15

Send delay time,

When TXD(236) is executed, data will

A410.15 (RS-232C Port

At next cycle (Also

 

 

0 to 99,990 ms

be sent from the RS-232C port after the

Settings Changing Flag)

can be changed

 

 

(0000 to 270F hex,

delay time set here.

 

with STUP (237).)

 

 

unit: 10 ms)

 

 

 

 

 

Default: 0000 hex

 

 

 

 

 

 

 

 

 

317

Page 340
Image 340
Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 Appendix C, Baud Rate, Serial Communications Mode, Data Format, Send Delay