Omron FQM1-CM001 Pulse Outputs, Section, Setting the Pulse Output Direction Priority Mode

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 207
Image 207
Setting the Pulse

Pulse Outputs

Section 7-6

Setting the Pulse

Output Direction

Priority Mode

Note

The pulse output direction priority mode for the PLS2(887) instruction is spec- ified by setting the ON/OFF bit status of A628.14 before executing the PLS2(887) instruction.

The priority mode setting in A628.14 applies to both pulse output 1 and 2.

Pulse Output Direction Priority Mode

Execute PLS2(887) with A628.14 OFF.

CW Output

@PLS2

#1

#0

D00000

Pulse output 1 CW direction Setting table: D00000

Absolute Position Priority Mode

D00000

8000

Target position: 8000 Hex

D00001

0000

 

D00002

C350

Target speed: 50 kHz

D00003

0000

 

D00004

0000

Starting speed: 0 Hz

D00005

0000

 

D00006

03E8

Acceleration rate: 1,000 Hz

D00007

03E8

Deceleration rate: 1,000 Hz

Execute PLS2(887) with A628.14 ON.

P_OnA628.14

Execution condition

 

@PLS2

 

The direction setting is

 

 

 

#1

Pulse output 1

 

ignored and the direction

 

 

 

 

#0

CW direction

is changed automatically.

 

 

Setting table: D00000

 

 

D00000

 

D00000

D00001

D00002

D00003

D00004

D00005

D00006

D00007

8000

0000

C350

0000

0000

0000

03E8

03E8

Target position: 8000 Hex

Target speed: 50 kHz

Starting speed: 0 Hz

Acceleration rate: 1,000 Hz

Deceleration rate: 1,000 Hz

7-6-13 Pulse Output Function Procedures

Pulse Outputs without Acceleration/Deceleration (PULS(886) + SPED(885))

This procedure shows how to use PULS(886) and SPED(885) to generate a single-phase pulse output without acceleration or deceleration. The number of output pulses cannot be changed during positioning.

1,2,3... 1. Determine pulse output port.

Select pulse output 1 or 2.

2.Wire the output.

Output: CW and CCW

Output power supply: 5 V DC

3.Make the necessary System Setup settings (Pulse Output Tab Page Op- eration Mode).

Set the pulse output operation mode (in the Pulse Output Tab Page Operation Mode) to relative pulse output, absolute linear pulse output, or absolute circular pulse output.

184

Page 207
Image 207
Omron FQM1-CM001 Pulse Outputs, Section, Setting the Pulse Output Direction Priority Mode, Absolute Position Priority Mode