Auxiliary Area Allocations

 

 

 

 

Appendix D

 

 

 

 

 

 

 

 

 

 

Address

Bits

 

 

Name

 

 

 

Function

 

 

 

 

 

 

 

 

 

A570

00

Adjustment Mode Command

Adjustment

Analog Input

 

OFF: Adjustment disabled.

 

 

Bits

 

Enable

 

 

ON: Adjustment enabled.

 

02

 

Analog Output 1

 

 

(Effective only when A575 is

 

 

When one of these bits is turned ON, the

 

 

 

 

 

 

03

 

Analog Output 2

 

 

5A5A hex.)

 

 

 

default value (offset or gain value) corre-

 

 

 

 

 

 

 

 

sponding to the selected I/O signal range is

 

 

 

 

 

 

 

 

transferred to Adjustment Mode Monitor

 

 

 

 

 

 

 

 

Area (A572 and A573).

 

07

 

 

 

Adjustment

OFF: Offset adjustment

 

 

 

 

 

 

Mode Specifier

ON: Gain adjustment

 

 

 

 

 

 

 

 

 

 

12

 

 

 

Adjustment

While this bit is ON, the offset or gain value will be incremented

 

 

 

 

 

Value Increment

by one resolution unit each 0.5 ms.

 

 

 

 

 

 

 

 

 

13

 

 

 

Adjustment

While this bit is ON, the offset or gain value will be decremented

 

 

 

 

 

Value Decre-

by one resolution unit each 0.5 ms.

 

 

 

 

 

 

ment

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

Adjustment

OFF to ON: Clears the adjustment data to the factory defaults.

 

 

 

 

 

Value Clear

 

 

 

 

 

15

 

 

 

Adjustment

OFF to ON: Reads the present value in the Adjustment Mode

 

 

 

 

 

Value Set

Monitor Area (A572 and A573) and saves this value to flash mem-

 

 

 

 

 

 

ory. This adjustment value will be used for the next normal mode

 

 

 

 

 

 

operation.

 

 

 

 

 

 

 

A571

00

Adjustment Mode Status

Adjustment

ON when an operational error has been made, such as turning

 

 

 

 

 

Operation Error

ON both the Analog Input and Analog Output 2 Adjustment

 

 

 

 

 

 

Enable Bits at the same time.

 

 

 

 

 

 

 

 

 

15

 

 

 

Adjustment

ON during adjustment mode operation (when A575 contains

 

 

 

 

 

Mode Started

5A5A hex).

 

 

A572

00 to 15

Adjustment Mode Monitor

Both Analog

Setting Offset Mon-

 

The values in these

10 to 10 V: FE0C to

 

 

(Effective only when A575 is

Input and Ana-

itor

 

words can be over-

01F4 hex

 

 

5A5A hex.)

 

log Outputs

 

 

written directly,

• 0 to 10 V, 0 to 5 V, 1

 

 

 

 

 

 

 

 

without using the

to 5 V: FF38 to 00C8

 

 

 

 

 

 

 

 

Adjustment Value

hex

 

 

 

 

 

 

 

 

Increment/Decre-

 

A573

00 to 15

 

 

 

 

Gain Value Monitor

 

10 to 10 V: 1194 to

 

 

 

 

 

ment Bits.

 

 

 

 

 

 

 

 

 

157C hex

 

 

 

 

 

 

 

 

 

• 0 to 10 V, 0 to 5 V, 1

 

 

 

 

 

 

 

 

 

to 5 V: 0ED8 to 1068

 

 

 

 

 

 

 

 

 

hex

 

 

 

 

 

 

 

 

 

 

A574

00 to 15

 

 

 

Analog Inputs

Number of Average

 

Indicates the number of values to be aver-

 

 

 

 

 

 

Value Samples in

 

aged to obtain the Offset/Gain Value Moni-

 

 

 

 

 

 

Adjustment Mode

 

tor values in adjustment mode. The number

 

 

 

 

 

 

 

 

of samples can be set between 0000 and

 

 

 

 

 

 

 

 

0040 hex (0 to 64). Set this parameter

 

 

 

 

 

 

 

 

before turning ON the Adjustment Enable

 

 

 

 

 

 

 

 

Bit.

 

A575

00 to 15

Adjustment Mode Password

 

5A5A hex: Adjustment mode enabled.

 

 

 

 

 

 

 

Other value: Adjustment mode disabled.

 

 

 

 

 

 

 

A600

00 to 15

High-speed Counter 1 PV

 

Range: 8000 0000 to 7FFF FFFF

 

 

 

 

 

 

 

Note For a Linear Counter, high-speed counter overflows/under-

A601

00 to 15

 

 

 

 

 

 

 

 

 

 

flows are checked when the PV is read (i.e., when Module inter-

A602

00 to 15

High-speed Counter 2 PV

 

 

nal I/O is refreshed).

 

 

A603

00 to 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A604 to

00 to 15

High-

 

For following

PV of absolute

Contains the number of rotations data (PV) read from the

A605

 

speed

 

counter modes

number of rota-

Encoder when the SEN signal is input to the Servo Driver.

 

 

Counter

 

• Absolute linear

tions

8000 0000 to 7FFF FFFF hex

 

 

 

1

 

(CW)

 

 

 

 

 

 

 

 

 

• Absolute circular

 

 

 

 

 

 

 

 

 

• Absolute linear

 

 

 

 

 

 

 

 

 

(CW+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For following

Monitor data

• When monitoring counter movements (mode 1), contains the

 

 

 

 

counter modes

 

absolute value of the amount of change in the PV of the high-

 

 

 

 

• Linear counter

 

speed counter over the specified sampling time as a 8-digit

 

 

 

 

• Circular counter

 

hexadecimal value (0000 0000 to FFFF FFFF hex).

 

 

 

 

 

• When monitoring the counter frequency (mode 2), contains the

 

 

 

 

 

 

 

 

 

 

 

 

frequency of the high-speed counter calculated from the PV of

 

 

 

 

 

 

the high-speed counter between 0 and 7A120 hex (0 and 500

 

 

 

 

 

 

kHz).

 

 

354