Pulse Outputs

Section 7-6

(3) Use this function for positioning.

Allowed Startup Conditions for Pulse Output Operations (with Output Stopped)

The following table shows when an independent mode pulse output (SPED(885) independent mode, ACC(888) independent acceleration mode, or ACC(888) independent deceleration mode) can be started when pulses are not being output.

Startup conditions and status

 

Startup mode and conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

Relative

Relative

Absolute

Absolute

 

Absolute

Absolute

 

 

pulse output

pulse output

linear CW

linear CCW

 

circular CW

circular

 

 

CW

CCW

 

 

 

 

CCW

Relative

 

OK

OK

---

---

 

---

---

 

 

 

 

 

 

 

 

 

Absolute

Target position >

---

---

OK

OK with

 

---

---

linear

Present position

 

 

 

SPED(885),

 

 

 

 

 

 

 

 

ACC(888)

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

with

 

 

 

 

 

 

 

 

PLS2(887)

 

 

 

 

 

 

 

 

 

 

 

 

 

Target position <

---

---

OK with

 

 

---

---

 

Present position

 

 

SPED(885),

 

 

 

 

 

 

 

 

ACC(888)

 

 

 

 

 

 

 

 

Disabled

 

 

 

 

 

 

 

 

with

 

 

 

 

 

 

 

 

PLS2(887)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Target position =

---

---

No

No

 

---

---

 

Present position

 

 

 

 

 

 

 

Absolute

Target position >

---

---

---

---

 

OK

OK

circular

Present position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Target position <

---

---

---

---

 

OK

OK

 

Present position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Target position =

---

---

---

---

 

OK

OK

 

Present position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The following table shows when a continuous mode pulse output (SPED(885) continuous mode, ACC(888) continuous acceleration mode, or ACC(888) continuous deceleration mode) can be started when pulses are not being out- put..

Startup conditions and status

 

Startup mode and conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

Relative

Relative

Absolute

Absolute

 

Absolute

Absolute

 

 

pulse output

pulse output

linear CW

linear CCW

 

circular CW

circular

 

 

CW

CCW

 

 

 

 

CCW

Relative

 

OK

OK

---

---

 

---

---

 

 

 

 

 

 

 

 

 

Absolute

Target position =

---

---

OK

OK

 

---

---

linear

Maximum value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Target position =

---

---

OK

OK

 

---

---

 

Minimum value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Absolute

Target position =

---

---

---

---

 

OK

OK

circular

Maximum value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Target position =

---

---

---

---

 

OK

OK

 

Minimum value

 

 

 

 

 

 

 