Synchronous Data Refresh

Section 5-4

Synchronous Data

Normal (via Ladder)

Counter 1 values

Counter 2 values

Pulse output 1

Pulse output 2

Analog input

Analog output 1

Analog output 2

Inner I/O input (Built-in input)

System Setup Select Synchronous Data

Set in upper 2 words

System Setup Select Synchronous Data

Set in lower 2 words

4 words of data transferred for each Module

Example: 4 words of data sent by Motion Control Module #1

+0

Counter 1 values

 

+1

 

Transfer

+2

Pulse output 1

 

+3

 

 

Above example: Motion Control Module #1 sends its high-speed counter 1 PV and pulse output 1 PV as the synchronous data link bits.

Note

(1)

Synchronous data for Coordinator Modules is fixed to general-purpose

 

 

(ladder execution results) data.

 

(2)

If there is no synchronous data to be sent, select no data for Select Syn-

 

 

chronous Data in the System Setup to shorten the synchronous data

 

 

transfer time.

 

(3)

Auxiliary Area data is transferred when input and output refresh method

 

 

is set to Immediate refresh and the synchronous data is set to an analog

 

 

input or analog output value in the System Setup.

5-4-3

Synchronous Data Link Bit Area

 

 

 

 

Synchronous Data

Word

Bits

Method for selecting type of synchronous data

Link Bit Areas in

address

 

 

Coordinator and

(See note

 

 

Motion Control

1.)

 

 

Modules

 

 

 

Sent from Coordina-

CIO 0200

00 to 15

Fixed to general-purpose data (e.g., ladder execution results)

tor Module

 

 

 

 

 

CIO 0201

00 to 15

 

 

 

 

 

 

 

 

 

 

 

CIO 0202

00 to 15

Fixed to general-purpose data (e.g., ladder execution results)

 

 

 

 

 

 

 

CIO 0203

00 to 15

 

 

 

 

 

Sent from Motion

CIO 0204

00 to 15

Set using upper 2 words of Select Synchronous Data in the System

Control Module #1

 

 

Setup for Motion Control Module #1.

CIO 0205

00 to 15

 

 

 

 

 

 

 

 

 

 

CIO 0206

00 to 15

Set using lower 2 words of Select Synchronous Data in the System

 

 

 

 

Setup for Motion Control Module #1.

 

 

CIO 0207

00 to 15

 

 

 

 

 

 

 

Sent from Motion

CIO 0208

00 to 15

Set using upper 2 words of Select Synchronous Data in the System

Control Module #2

 

 

Setup for Motion Control Module #2.

CIO 0209

00 to 15

 

 

 

 

 

 

 

 

 

 

CIO 0210

00 to 15

Set using lower 2 words of Select Synchronous Data in the System

 

 

 

 

Setup for Motion Control Module #2.

 

 

CIO 0211

00 to 15

 

 

 

 

 

 

 

Sent from Motion

CIO 0212

00 to 15

Set using upper 2 words of Select Synchronous Data in the System

Control Module #3

 

 

Setup for Motion Control Module #3.

CIO 0213

00 to 15

 

 

 

 

 

 

 

 

 

 

CIO 0214

00 to 15

Set using lower 2 words of Select Synchronous Data in the System

 

 

 

 

Setup for Motion Control Module #3.

 

 

CIO 0215

00 to 15

 

 

 

 

 

 

 

 

110

Page 133
Image 133
Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 Synchronous Data Link Bit Area, Ladder execution results data, Transfer time