Auxiliary Area Allocations

 

 

Appendix D

 

 

 

 

 

 

Address

Bits

Name

 

 

Function

 

 

 

 

A520

00 to 15

Interrupt Counter 0 Counter SV

Used for interrupt input 0 in counter mode.

 

 

 

Sets the count value at which the interrupt task will start. Interrupt

 

 

 

task 000 will start when interrupt counter 0 has counted this num-

 

 

 

ber of pulses.

 

 

 

 

Setting range: 0000 to FFFF

 

 

 

 

A521

00 to 15

Interrupt Counter 1 Counter SV

Used for interrupt input 1 in counter mode.

 

 

 

Sets the count value at which the interrupt task will start. Interrupt

 

 

 

task 001 will start when interrupt counter 1 has counted this num-

 

 

 

ber of pulses.

 

 

 

 

Setting range: 0000 to FFFF

 

 

 

 

A522

00 to 15

Interrupt Counter 2 Counter SV

Used for interrupt input 2 in counter mode.

 

 

 

Sets the count value at which the interrupt task will start. Interrupt

 

 

 

task 002 will start when interrupt counter 2 has counted this num-

 

 

 

ber of pulses.

 

 

 

 

Setting range: 0000 to FFFF

 

 

 

 

A523

00 to 15

Interrupt Counter 3 Counter SV

Used for interrupt input 3 in counter mode.

 

 

 

Sets the count value at which the interrupt task will start. Interrupt

 

 

 

task 003 will start when interrupt counter 3 has counted this num-

 

 

 

ber of pulses.

 

 

 

 

Setting range: 0000 to FFFF

 

 

 

 

A524

00 to 15

Interrupt Counter 0 Counter PV

These words contain the interrupt counter PVs for interrupt input

 

 

 

0 to 3 operating in counter mode.

A525

00 to 15

Interrupt Counter 1 Counter PV

The counter PV starts decrementing from the counter SV. When

 

 

 

A526

00 to 15

Interrupt Counter 2 Counter PV

the counter PV reaches the 0, the PV is automatically reset to the

 

 

 

SV.

 

A527

00 to 15

Interrupt Counter 3 Counter PV

 

Range: 0000 to FFFF

 

 

 

 

 

 

 

A530

00

DM Write Request Bit (Coordinator Module to

DM data transfer is executed from the Coordinator Module to

 

 

Motion Control Module)

Motion Control Module when this bit turns ON.

 

 

 

 

 

01

DM Read Request Bit (Motion Control Module to

DM data transfer is executed from the Motion Control Module to

 

 

Coordinator Module)

Coordinator Module when this bit turns ON.

A531

00 to 15

Slot No. of Motion Control Module for DM Trans-

Specifies the slot number (in 4-digit hexadecimal) for the Motion

 

 

fer

Control Module with which DM data is to be transferred.

 

 

 

0001: Motion Control Module #1

 

 

 

0002: Motion Control Module #2

 

 

 

0003: Motion Control Module #3

 

 

 

0004: Motion Control Module #4

 

 

 

 

A532

00 to 15

DM Transfer Size (number of words)

Specifies the size, in number of words, of the DM data to be trans-

 

 

 

ferred.

 

 

 

 

0001 to 01F3 hex (1 to 499 words)

 

 

 

 

A533

00 to 15

First DM Transfer Source Word

Specifies the first address of the DM transfer source in the Coor-

 

 

 

dinator Module or Motion Control Module.

 

 

 

0000 to 7FFF hex

 

 

 

 

 

A534

00 to 15

First DM Transfer Destination Word

Specifies the first address of the DM transfer destination in the

 

 

 

Coordinator Module or Motion Control Module.

 

 

 

0000 to 7FFF hex

 

 

 

 

 

A535

14

Transfer Error Flag

Turns ON when a DM data transfer error occurs.

 

 

 

 

 

15

Transfer Busy Flag

Turns ON during DM data transfer and turns OFF when the trans-

 

 

 

fer has been completed.

 

 

 

 

A550

00 to 15

Analog Input PV

Contains the value input from the analog input port (using either

 

 

 

the END refresh or immediate refresh) in 4-digit hexadecimal.

 

 

 

The PV range depends on the input range:

 

 

 

• 0 to 10 V:

FE70 to 20D0 hex

 

 

 

• 0 to 5 V or 1 to 5 V:

FF38 to 1068 hex

 

 

 

10 to 10 V:

DDA0 to 2260 hex

 

 

 

 

 

A552

00

Analog Input Status

User Adjustment

 

OFF: Not adjusted

 

 

 

Completed

 

ON: Adjustment completed

 

 

 

 

 

 

 

07

 

Analog Sampling

 

OFF: Not started

 

 

 

Started

 

ON: Started

 

 

 

 

 

 

 

08

 

Factory Adjustment

 

OFF: No Error

 

 

 

Data Error

 

ON: Error (Checked at power ON.)

 

 

 

 

 

 

 

09

 

User Adjustment

 

OFF: No Error

 

 

 

Data Error

 

ON: Error (Checked at power ON.)

 

 

 

 

 

 

 

15

 

Analog Sampling

 

OFF: Normal sampling

 

 

 

Overlap

 

ON: The next sampling operation occurred

 

 

 

 

 

before the present sampling operation com-

 

 

 

 

 

pleted.

352