System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

FQM1-MMA21 Motion Control Modules with Analog I/O

 

 

 

 

 

 

 

 

 

 

Address

Bits

Name

 

 

Function

 

Controlled

 

 

 

 

 

 

 

by

A550

00 to 15

Analog Input PV

Contains the value input from the analog input port (using either the END

 

Module

 

 

 

refresh or immediate refresh) in 4-digit hexadecimal.

 

 

 

 

 

The PV range depends on the input range:

 

 

 

 

 

• 0 to 10 V:

FE70 to 20D0 hex

 

 

 

 

 

• 0 to 5 V or 1 to 5 V:

FF38 to 1068 hex

 

 

 

 

 

10 to 10 V:

DDA0 to 2260 hex

 

 

 

 

 

 

 

 

 

 

A552

00

Analog Input Sta-

User Adjustment Com-

 

OFF: Not adjusted

 

 

 

 

tus

pleted

 

ON: Adjustment completed

 

 

 

01 to 06

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

07

 

Analog Sampling Started

 

OFF: Not started

 

 

 

 

 

 

 

ON: Started

 

 

 

08

 

Factory Adjustment Data

 

OFF: No Error

 

 

 

 

 

Error

 

ON: Error (Checked at power ON.)

 

 

 

 

 

 

 

 

 

 

 

09

 

User Adjustment Data

 

OFF: No Error

 

 

 

 

 

Error

 

ON: Error (Checked at power ON.)

 

 

 

 

 

 

 

 

 

 

 

10 to 14

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

15

 

Analog Sampling Overlap

OFF: Normal sampling

 

 

 

 

 

 

 

ON: The next sampling operation occurred before

 

 

 

 

 

 

the present sampling operation completed.

 

 

 

 

 

 

 

 

 

A559

01 to 15

Number of Analog

Indicates the number of data samples actually input since sampling started.

 

 

 

 

Samples

 

 

 

 

 

 

 

 

 

 

A560

00 to 15

Analog Output 1

When an END refresh is selected, the 4-digit hexadecimal value set here by the

With immedi-

 

 

Output Value

user is output from analog output port 1.

 

ate refresh:

 

 

 

When immediate refreshing is selected, the 4-digit hexadecimal value being out-

Module

 

 

 

put from analog output port 1 is stored here for monitoring. The output value

With END

 

 

 

range depends on the output range, as shown below.

 

refresh: User

 

 

 

• 0 to 10 V, 0 to 5 V or 1 to 5 V: FF38 to 1068 hex

 

 

 

 

 

10 to 10 V: EA84 to 157C hex

 

 

 

 

 

Note

 

 

 

 

 

 

 

1. Set the analog output method (END or immediate refreshing) with the System

 

 

 

 

Setup’s output method setting. A setting of 0 hex specifies an END refresh.

 

 

 

 

This setting applies to both analog output 1 and 2.

 

 

 

 

 

2. Specify the output range with the output 1 setting.

 

 

 

 

 

 

 

A561

00 to 15

Analog Output 2

This word has the same settings as the analog output 1 output value (A560),

 

 

 

Output Value

above. (When an END refresh is selected, set the value to output from analog

 

 

 

 

output port 2. When an immediate refresh is selected, the output value is stored

 

 

 

 

here for monitoring.)

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

1. Set the analog output method (END or immediate refresh) with the System

 

 

 

 

Setup’s output method setting. A setting of 0 hex specifies an END refresh.

 

 

 

 

This setting applies to both analog output 1 and 2.

 

 

 

 

 

2. Specify the output range with the output 2 setting.

 

 

336