Basic Operating Procedure

Basic Operating Procedure

Section 1-6

NS-series PT

1-6 Basic Operating Procedure Smart Active Parts

NT

Coordinator Module

Link

 

 

FQM1

Protocol

Servo parameters

conversion

RS-422A

 

W-series or SMART STEP Servo Driver

W-series or SMART STEP Servo Driver

No-protocol (Custom) Communications System via RS-422A Port

No-protocol communications allow simple data transmissions, such as input- ting bar code data and outputting printer data using communications port I/O instructions TXD(236) and RXD(235). The start and end codes can be set with no-protocol communications.

Coordinator Module

Applicable Ports

Coordinator Module

Peripheral

RS-232C

RS-422A

No

Yes

Yes

Note Set the serial communications mode in the System Setup to "non-procedural."

RXD(235) instruction

RS-422A

Manual background TXD(236) instruction

1-6 Basic Operating Procedure

The following procedure outlines the normal steps to operate the FQM1.

1,2,3... 1. Installation

Connect the Power Supply Unit, Coordinator Module, Motion Control Mod- ules, and End Module. Refer to 3-1-4 Connecting FQM1 Components for details.

Mount the FQM1. Refer to 3-1-5 DIN Track Installation for details

2.Wiring

Connect the power supply wiring and ground. Refer to 3-2-1 Wiring Power Supply Units for details.