Auxiliary Area Allocations

 

Appendix D

 

 

 

 

 

 

 

Address

Bits

 

Name

 

Function

 

 

 

 

 

 

 

A606 to

00 to 15

High-

For following

 

PV of absolute

Same as for A604 and A605 for high-speed counter 1 except that

A607

 

speed

counter modes

 

number of rota-

measuring the high-speed counter frequency is not possible for

 

 

Counter

• Absolute linear

 

tions

high-speed counter 2.

 

 

2

(CW)

 

 

 

 

 

 

• Absolute circular

 

 

 

 

 

 

• Absolute linear

 

 

 

 

 

 

(CW+)

 

 

 

 

 

 

 

 

 

 

 

 

 

For following

 

Monitor data

 

 

 

 

counter modes

 

 

 

 

 

 

• Linear counter

 

 

 

 

 

 

• Circular counter

 

 

 

 

 

 

 

 

 

A608

00

High-

Target Comparison In-progress Flag

OFF: Target value comparison is not being performed for

 

 

speed

 

 

 

CTBL(882).

 

 

counter 1

 

 

 

Note This flag is always OFF for range comparison.

 

 

status

 

 

 

 

 

 

 

 

ON: Target value comparison is being performed for CTBL(882).

 

 

 

 

 

 

 

 

 

 

 

 

Note Target comparison is continued without interruption once it

 

 

 

 

 

 

has been started (as opposed to range comparison), so this flag

 

 

 

 

 

 

can be used to check whether target comparison is in progress.

 

01

 

PV Overflow/Underflow Flag

OFF: There is no counter overflow or underflow in Linear Counter

 

 

 

 

 

 

Mode. This flag will always be OFF in Circular Counter Mode.

 

 

 

 

 

 

ON: There is a counter overflow or underflow in Linear Counter

 

 

 

 

 

 

Mode. The counter PV will be fixed at the overflow or underflow

 

 

 

 

 

 

limit. This flag will be cleared when the High-speed Counter Start

 

 

 

 

 

 

Bit is turned OFF.

 

 

 

 

 

 

03

 

Phase Z Input Reset Flag (ON for

ON for one cycle when the counter PV is reset with the counter

 

 

 

one cycle)

 

reset method set to a phase Z + software reset.

 

 

 

 

 

 

Note This flag will turn ON for one cycle after the counter PV is

 

 

 

 

 

 

reset if the phase Z signal (reset input) turns ON while the High-

 

 

 

 

 

 

speed Counter Reset Bit (A610.01) is ON.

 

04

 

Absolute No. of Rotations Read Error

OFF: No error

 

 

 

Flag

 

ON: Error

 

 

 

 

 

 

05

 

Absolute No. of Rotations Read

OFF: Rotations being read or reading has not been executed.

 

 

 

Completed Flag

 

ON: Reading has been completed (Turned ON when serial recep-

 

 

 

 

 

 

tion of the number of rotations has been completed.)

 

 

 

 

 

 

06

 

Measuring Flag (measurement mode

OFF: Changes in the counter PV or the counter frequency is not

 

 

 

1 or 2)

 

being measured.

 

 

 

Note Valid when Counter Data Dis-

ON: Changes in the counter PV or the counter frequency is being

 

 

 

play in System Setup is set to

measured.

 

 

 

Counter Movements (mode 1) or Fre-

In measurement mode 1, this flag will turn ON at the beginning of

 

 

 

quency (mode 2).

 

the sampling time after the Measurement Start Bit (A610.02) is

 

 

 

 

 

 

turned ON.

 

 

 

 

 

 

07

 

High-speed Counter Operating Flag

OFF: Counter is not operating.

 

 

 

 

 

 

ON: Counter is operating.

 

 

 

 

 

 

 

08

 

Count Latched Flag

 

OFF: Count has not been latched.

 

 

 

 

 

 

ON: Latching the count has been completed for the latch input.

 

 

 

 

 

 

12

 

Absolute Offset Preset Error Flag

OFF: No error occurred when saving the absolute offset.

 

 

 

 

 

 

ON: An error occurred when saving the absolute offset.

 

 

 

 

 

A609

00

High-

Target Comparison In-progress Flag

Same as for high-speed counter 1.

 

 

speed

 

 

 

 

 

01

PV Overflow/Underflow Flag

 

 

counter 2

 

 

03

status

Phase Z Input Reset Flag (ON for

 

 

 

 

one cycle)

 

 

 

 

 

 

 

 

04

 

Absolute No. of Rotations Read Error

 

 

 

 

Flag

 

 

 

 

 

 

 

 

05

 

Absolute No. of Rotations Read

 

 

 

 

Completed Flag

 

 

 

06

 

Measuring Flag (measurement mode

 

 

 

 

1 or 2)

 

 

 

 

 

 

 

 

07

 

High-speed Counter Operating Flag

 

 

 

 

 

 

 

 

08

 

Count Latched Flag

 

 

 

 

 

 

 

 

12

 

Absolute Offset Preset Error Flag

 

 

 

 

 

 

 

 

355

Page 378
Image 378
Omron FQM1-CM001, FQM1-MMA21, FQM1-MMP21 operation manual Auxiliary Area Allocations, Appendix D, A606 to