Cyclic Refresh

Section 5-3

5-3 Cyclic Refresh

5-3-1 Outline

Coordinator Module

CIO 0000

to

CIO 0099

CIO 0100

to

CIO 0104

CIO 0105

to

CIO 0109

CIO 0110

to

CIO 0114

CIO 0115

to

CIO 0119

CIO 0120

to

CIO 0124

CIO 0125

to

CIO 0129

CIO 0130

to

CIO 0134

CIO 0135

to

CIO 0139

Status information, general-purpose I/O, and other information for each Motion Control Module in the Cyclic Refresh Area of the Coordinator Module are refreshed every Coordinator Module cycle (asynchronous to the Motion Control Module cycles).

As shown in the following diagram, 10 words per Motion Control Module (5 output words and 5 input words) are allocated according to the Motion Control Module slot number (#1 to #4 in the following diagram) in the Cyclic Refresh Area of the Coordinator Module (CIO 0100 to CIO 0139).

Motion Control

Motion Control

Motion Control

Motion Control

Module #1

Module #2

Module #3

Module #4

CIO 0100

CIO 0100

CIO 0100

CIO 0100

to

to

to

to

CIO 0104

CIO 0104

CIO 0104

CIO 0104

CIO 0105

CIO 0105

CIO 0105

CIO 0105

to

to

to

to

CIO 0109

CIO 0109

CIO 0109

CIO 0109

Note Cyclic refreshing between the Coordinator Module and Motion Control Mod- ules is asynchronous. Information may take up to 2 cycles to be received.

5-3-2 Applications

In addition to the Synchronous Data Link Bit Area, normal data exchange between the Coordinator Module and Motion Control Modules is possible using the Cyclic Refresh Area.

Information for which high-speed data exchange between Modules is not required can be allocated anywhere, and a ladder program written for the Coordinator Module and Motion Control Modules to access these areas dur- ing operation can be created.

106

Page 129
Image 129
Omron FQM1-CM001, FQM1-MMA21, FQM1-MMP21 operation manual Cyclic Refresh, Applications