current consumption, 45

CX-Programmer,92, 95

Analog Input/Output Tab Page, 325 connecting cables, 234, 238 connections, 235

methods, 237

Cycle Time Settings, 312

Cycle Time Tab Page, 321 models, 32

Module Settings Tab Page, 321 Other Tab Page, 321 overview, 8, 234 Peripheral Port Settings, 313

Peripheral Port Settings for Host Link, 313 Peripheral Port Settings for NT Link, 314

Peripheral Port Settings for Peripheral Bus (ToolBus), 314

Peripheral Service Time Settings, 320 Pulse Input Tab Page, 322, 324 Pulse Output Tab Page, 323

RS-232 Port Settings for No-protocol Communications (RS-232C),317

RS-232C Port Settings for Host Link, 315 RS-232C Port Settings for NT Link, 316

RS-232C Port Settings for Peripheral Bus (ToolBus), 316 RS-232C Port Settings for PLC Link (PC Link (Slave)), 318

RS-422A Port Settings for No-protocol Communications (Non-procedural),319

RS-422A Port Settings for Serial Gateway, 319 Startup Mode Setting, 312

Sync Settings between Modules, 311 cycle time, 19

computing, 288 errors, 249

maximum cycle time, 344, 349 present cycle time, 344, 349 settings, 326

Cycle Time PV, 116

Cycle Time Too Long Flag, 116, 249, 346, 349

Cyclic Refresh Bit Area, 106, 107, 302

allocations, 108

cyclic refreshing, 94, 105, 106

D

data areas addressing, 271

data control instructions execution times, 369

data exchange

between Modules, 105

data formats, 276

Data Memory (DM) Area, 307

data movement instructions execution times, 364

data shift instructions execution times, 365

debugging, 14, 120

debugging instructions execution times, 372

deceleration rate, 182 trapezoidal, 193

decrement instructions execution times, 365

decrement pulse inputs, 153

DI(802) instruction disabling all interrupts, 141

diagnosis, 120

Differentiate Monitor Completed Flag, 351

Differentiation Flags, 270

Differentiation Overflow Error Flag, 344, 350

dimensions, 43

Servo Relay Units, 79

DIN Track, 57, 59

DM data transfer, 105, 112 executing, 113 programming example, 114

DM Read Request Bit, 113

DM Transfer Size, 113

DM Write Request Bit, 113

downwardly differentiated instructions, 280

ducts wiring, 53

E

EC Directives, xix

EI(694) instruction enabling all interrupts, 141

electrical noise, 85

electronic cam control, 186

End Modules

current consumption, 45 dimensions, 43 models, 32 overview, 6

377