System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Note Always set the Circular Maximum Count when setting any of the circular operation modes.

FQM1-MMA21 Motion Control Modules with Analog I/O

CX-Programmer: Pulse Input Tab Page

Address

Bits

Function

Remarks

When setting

 

 

 

 

 

is read

 

 

 

 

 

 

+320

00 to 03

High-speed

Input method

0 hex: Phase differential x1

At power ON

 

 

counter 1 (Counter

 

1 hex: Phase differential x2

 

 

 

1)

 

2 hex: Phase differential x4

 

 

 

 

 

 

 

 

 

 

3 hex: Increment/decrement pulse inputs

 

 

 

 

 

4 hex: Pulse + direction inputs

 

 

 

 

 

 

 

 

04 to 07

 

Reset method

0 hex: Software reset

 

 

 

 

 

1 hex: Phase Z and software reset

 

 

 

 

 

 

 

 

08 to 11

 

Counting speed

0 hex: 50 kHz

 

 

 

 

 

1 hex: 500 kHz

 

 

 

 

 

 

 

 

12 to 15

 

Counter operating

0 hex: Linear counter

 

 

 

 

mode (Counter opera-

1 hex: Circular counter

 

 

 

 

tion)

2 hex: Absolute linear counter (CW)

 

 

 

 

 

 

 

 

 

 

3 hex: Absolute circular counter

 

 

 

 

 

4 hex: Absolute linear counter (CW+)

 

 

 

 

 

 

 

+321

00 to 03

 

Counter data to moni-

0 hex: Do not monitor (Non-monitor)

 

 

 

 

tor (Counter data dis-

1 hex: Counter PV changes (Counter movements

 

 

 

 

play)

(mode 1))

 

 

 

 

 

2 hex: Frequency (mode 2)

 

 

 

 

 

Note The frequency (mode 2) can be set only for

 

 

 

 

 

high-speed counter 1.

 

 

 

 

 

 

 

 

04 to 15

 

Reserved

 

 

 

 

 

 

 

 

+322

00 to 15

 

Sampling time (for

Sets the sampling time for monitoring counter PV

 

 

 

 

mode 1 only)

changes (mode 1)

 

 

 

 

 

0000: Cycle time

 

 

 

 

 

0001 to 270F hex: 1 to 9,999 ms

 

 

 

 

 

(unit: 1 ms)

 

 

 

 

 

Note This setting is valid only when the Counter

 

 

 

 

 

Data Display (bits 00 to 03 of +321) is set to 1 hex

 

 

 

 

 

(mode 1).

 

+323

00 to 03

High-speed

Input method

Same as for high-speed counter 1 except that fre-

 

 

 

counter 2 (Counter

 

quency measurement (Counter data to monitor, bit

 

 

04 to 07

Reset method

 

 

2)

00 to 03 of +324: 02 hex) cannot be set for high-

 

 

08 to 11

 

Counting speed

speed counter 2.

 

 

 

 

 

 

 

 

12 to 15

 

Counter operating

 

 

 

 

 

mode (Counter opera-

 

 

 

 

 

tion)

 

 

+324

00 to 03

 

Counter data to moni-

 

 

 

 

 

tor (Counter data dis-

 

 

 

 

 

play)

 

 

 

04 to 15

 

Reserved

 

 

 

 

 

 

 

 

+325

00 to 15

 

Sampling time (for

 

 

 

 

 

mode 1 only)

 

 

+326 to 327

00 to 15

High-speed

Circular maximum

Sets the maximum circular counter value.

 

 

 

counter 1 (Counter

count

Range: 0000 0001 to FFFF FFFF hex

 

 

 

1)

 

 

 

 

 

Absolute encoder res-

0000 0001 to 0000 FFFF hex

 

 

 

 

 

 

 

 

olution

Note Set this value in pulses/rotation according to

 

 

 

 

 

 

 

 

 

 

the encoder dividing ratio set for the Servo Driver

 

 

 

 

 

and the input method multiplier set for the Module.

 

 

 

 

 

Example: If the Servo Driver setting is 1,000 and

 

 

 

 

 

the Module setting is x4, set FA0 (4,000).

 

+328 to 329

00 to 15

High-speed

Circular maximum

Same as for high-speed counter 1.

 

 

 

counter 2 (Counter

count

 

 

 

 

2)

 

 

 

 

 

Absolute encoder res-

 

 

 

 

 

 

 

 

 

 

olution

 

 

 

 

 

 

 

 

324

Page 347
Image 347
Omron FQM1-MMP21, FQM1-CM001 FQM1-MMA21 Motion Control Modules with Analog I/O, Address Bits Function Remarks When setting