Omron FQM1-MMA21, FQM1-CM001 One-shotPulse Output Function, Pulse Outputs, Section, Formula

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 199
Image 199
Formula:

Pulse Outputs

Section 7-6

Clock-generated pulses 7-6-7 One-shot Pulse Output Function (one of four possible settings)

Integer dividing ratio set according to the target frequency set by user.

Output pulses

(Actual output frequency)

Dividing circuit

Formula:

Actual frequency = Clock frequency INT (clock frequency/target frequency)

Note INT (clock frequency/target frequency) is the dividing ratio.

The difference between the target frequency and the actual frequency increases at higher frequencies. The following tables shows examples for a clock frequency of 20 MHz.

Target frequency (Hz)

Actual output frequency

 

 

952,382 to 1,000,000

1,000,000

 

 

909,092 to 952,381

952,381

 

 

869,566 to 909,091

909,091

 

 

.

.

.

.

.

.

 

 

487,806 to 500,000

500,000

 

 

476,191 to 487,805

487,805

 

 

465,117 to 476,190

476,190

 

 

.

.

.

.

.

.

 

 

198,021 to 200,000

100,806

 

 

196,079 to 198,020

198,020

 

 

194,176 to 196,078

196,078

 

 

.

.

.

.

.

.

 

 

49,876 to 50,000

50,000

 

 

49,752 to 49,875

49,875

 

 

4,929 to 49,751

49,751

 

 

.

.

.

.

.

.

 

 

402

402

 

 

401

401

 

 

400

400

 

 

7-6-7 One-shot Pulse Output Function

The one-shot pulse output function turns ON the output only for a specified time between 0.01 and 9,999 ms. Use the STIM(980) instruction to start the pulse output (turn the output from OFF to ON). After the time specified in STIM(980) has elapsed, the pulse output is automatically turned OFF (in the hardware).

176

Page 199
Image 199
Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 operation manual One-shotPulse Output Function, Pulse Outputs, Section, Formula