Omron FQM1-MMA21 Related Areas and Settings, 7-9-4, Analog Input FunctionsSection, System Setup

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 241
Image 241
7-9-4

Analog Input FunctionsSection 7-9

7-9-4

Related Areas and Settings

 

System Setup

 

 

 

 

 

 

 

 

 

 

Tab page

Function

 

Settings

Time when setting

 

 

 

 

 

 

becomes effective

 

 

 

 

 

 

Analog Input/

Both inputs

Input

0 hex:

END refresh

At power ON and

Output

 

and outputs

method

1 hex:

Immediate refresh (Refresh with PRV(881).)

start of operation

 

 

 

 

 

 

 

 

 

 

Output

0 hex:

END refresh

At power ON and

 

 

 

method

 

(Content of A560 and A561 is output as

start of operation

 

 

 

 

 

analog output after execution of END

 

 

 

 

 

 

instruction.)

 

 

 

 

 

1 hex:

Immediate refresh

 

 

 

 

 

 

(Analog output when SPED(885) or

 

 

 

 

 

 

ACC(888) is executed. A560 and A561

 

 

 

 

 

 

used for monitoring.)

 

 

 

 

 

 

 

 

 

 

Inputs

Input range

00 hex:

10 to 10 V

At power ON

 

 

 

 

01 hex:

0 to 10 V

 

 

 

 

 

02 hex:

1 to 5 V (4 to 20 mA)

 

 

 

 

 

03 hex:

0 to 5 V

 

 

 

 

 

 

 

 

 

 

Outputs

Output

00 hex:

10 to 10 V

At power ON

 

 

 

range

01 hex:

0 to 10 V

 

 

 

 

 

02 hex:

1 to 5 V

 

 

 

 

 

03 hex:

0 to 5 V

 

 

 

 

 

5A hex: Disable outputs (See note.)

 

 

 

 

 

Note Outputs can be disabled to shorten the I/O

 

 

 

 

 

refreshing time or reduce the Motion Control

 

 

 

 

 

Module’s power consumption.

 

 

 

 

 

 

 

 

 

 

 

Output stop

0 hex:

Clear outputs

 

 

 

 

function

1 hex:

Hold outputs

 

 

 

 

 

2 hex:

Maximum value

 

 

 

 

 

 

 

 

 

Outputs

Output

These parameters have the same settings as output

 

 

 

 

range

1, above.

 

 

 

 

 

 

 

 

 

 

 

Output stop

 

 

 

 

 

 

function

 

 

 

 

 

 

 

 

 

 

218

Page 241
Image 241
Omron FQM1-MMA21, FQM1-CM001 Related Areas and Settings, 7-9-4, Analog Input FunctionsSection, System Setup, Tab page