LED and Beeper Indicators

Good Read LED Duration

This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 10ms increments.

Follow these instructions to set this feature:

1.Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled.

2.Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead- ing zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc.

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.

4.Scan the barcode: SELECT GOOD READ LED DURATION SETTING.

5.Scan the appropriate three digits from the keypad in Appendix E, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 3 for some examples of how to set this feature.

 

Table 3. Good Read LED Duration Setting Examples

 

STEP

ACTION

 

EXAMPLES

 

1

Desired Setting

Good Read LED

 

 

 

stays on until next

20ms

150ms

2550ms (2.55 sec.)

 

 

trigger pull (00)

 

 

 

2

Divide by 10 (and pad with

002

015

255

leading zeroes)

000

 

 

 

 

 

3

 

Scan ENTER/EXIT PROGRAMMING MODE

 

4

Scan SELECT LABEL GONE TIMEOUT SETTING

 

5

Scan Three Characters

‘0’, ‘0’ and ‘0’

‘0’, ‘0’ and ‘2’

‘0’, ‘1’ and ‘5’

‘2’, ‘5’ and ‘5’

From Appendix E, Keypad

 

 

 

 

 

6

 

Scan ENTER/EXIT PROGRAMMING MODE

 

Product Reference Guide