Wand Emulation Interface

Introduction

This chapter provides feature/settings configuration for the Wand Emulation interface.

Wand Emulation Standard Factory Settings

Reference Appendix C, Standard Defaults for a listing of standard factory settings.

Wand Idle State

This feature specifies the level of the Wand output signal when the reader is idle.

TTL logic levels:

0V <= Low <= 0.7V

2.4V <= High <= 5.25V

NOTE

ENTER/EXIT PROGRAMMING MODE

Wand Idle State = Low

DEFAULT

Wand Idle State = High