Disable Character
Specifies the value of the
ASCII characters or any hex value from 0 to 0xFF can be selected.
NOTE
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
To set the value:
1.Determine the desired character or value. A setting of 0xFF indicates the Disable Charac- ter is not used (not available).
2.Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.
4.Scan the barcode: SELECT DISABLE CHARACTER SETTING.
5.Scan the appropriate two
6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 12 for some examples of how to set this feature.
| Table 12. Disable Character Setting Examples |
| ||||
STEP | ACTION |
|
| EXAMPLES |
| |
1 | Desired character/value | ‘d’ | ‘}’ | ‘D’ | Disable Command | |
Not Used | ||||||
|
|
|
|
| ||
2 | Hex equivalent | 0x64 | 0x7D | 0x44 | 0xFF | |
3 | Scan ENTER/EXIT PROGRAMMING MODE |
| ||||
4 | Scan SELECT DISABLE CHARACTER VALUE SETTING |
| ||||
5 | Scan Two Characters From | ‘6’ and ‘4’ | ‘7’ and ‘D’ | ‘4’ and ‘4’ | ‘F’ AND ‘F’ | |
Appendix E, Keypad | ||||||
|
|
|
|
| ||
6 | Scan ENTER/EXIT PROGRAMMING MODE |
|
74 | Gryphon™ I GD4100 |