Intercode Delay

Intercode Delay

Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds.

Follow these instructions to set this feature:

1.Determine the desired setting.

2.Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.

4.Scan the barcode: SELECT INTERCODE DELAY SETTING.

5.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 16 for some examples of how to set this feature.

 

Table 16. Wedge Intercode Delay Examples

 

STEP

ACTION

 

 

EXAMPLES

 

1

Desired Setting

No Delay

5 Seconds

60 Seconds

99 Seconds

2

Pad with leading zero(es)

00

05

60

99

3

Scan ENTER/EXIT PROGRAMMING MODE

 

4

Scan SELECT INTERCODE DELAY SETTING

 

5

Scan Two Characters From

‘0’ and ‘0’

‘0’ and ‘5’

‘6’ and ‘0’

‘9’ AND ‘9’

Appendix E, Keypad

 

 

 

 

 