Datalogic Scanning I GD4100 manual Code 39 Length 2 Setting Examples

Models: I GD4100

1 324
Download 324 pages 4.78 Kb
Page 184
Image 184

Symbologies

Code 39 — cont.

Code 39 Set Length 2

This feature specifies one of the barcode lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.

The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).

Follow these instructions to set this feature:

1.Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.

3.Scan the barcode: SELECT CODE 39 LENGTH 2 SETTING.

4.Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indica- tion after the last character.

If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

5.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 22 for some examples of how to set this feature.

 

Table 22. Code 39 Length 2 Setting Examples

 

STEP

ACTION

 

EXAMPLES

 

1

Desired Setting

00 (Ignore This

07 Characters

15 Characters

50 Characters

Length)

 

 

 

 

 

2

 

Scan ENTER/EXIT PROGRAMMING MODE

 

3

 

Scan SELECT CODE 39 LENGTH 2 SETTING

 

4

Scan Two Characters From

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

Appendix E, Keypad

‘0’ and ‘0’

 

 

 

 

 

5

 

Scan ENTER/EXIT PROGRAMMING MODE

 

182