Label Gone Timeout

Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read

Follow these instructions to set this feature:

1.Determine the desired setting in milliseconds.

2.Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead- ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.

3.Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.

4.Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING.

5.Scan the appropriate three alpha-numeric characters from the keypad in Appendix E, Key- pad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character.

If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

NOTE

6.Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See Table 2 for some examples of how to set this feature.

 

Table 2. Timeout Setting Examples

 

 

STEP

ACTION

 

EXAMPLES

 

1

Desired Setting

50ms

150ms

1800ms (1.8 sec.)

2550ms (2.55 sec.)

2

Divide by 10 (and pad with

015

180

255

leading zeroes)

005

 

 

 

 

 

3

 

Scan ENTER/EXIT PROGRAMMING MODE

 

4

Scan SELECT LABEL GONE TIMEOUT SETTING

 

5

Scan Three Characters

‘0’, ‘0’ and ‘5’

‘0’, ‘1’ and ‘5’

‘1’, ‘8’ and ‘0’

‘‘2’, ‘5’ and ‘5’

From Appendix E, Keypad

 

 

 

 

 

6

 

Scan ENTER/EXIT PROGRAMMING MODE

 

Product Reference Guide

25

Page 27
Image 27