Symbologies

266 Gryphon™ I GD4100

Standard 2 of 5 — cont.

Standard 2 of 5 Set Length 1

This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 1 is
the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the barcode’s check and data characters.
The length can be set from 1 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50). Pad the number with leading
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT STANDARD 2 OF 5 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the
length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table 33 for some examples of how to set this feature.
Table 33. Standard 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting 01 Character 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4Scan Two Characters From
Appendix E, Keypad ‘0’ and ‘1’ ‘0’ and ‘7 ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.