LED and Beeper Indications

LED and Beeper Indications

INDICATION

DESCRIPTION

LED

BEEPER

 

 

 

 

 

 

 

 

 

The reader is in the process of pow-

 

Reader beeps four times at highest

Power-up Beep

 

frequency and volume upon power-

ering-up.

 

 

 

up.

 

 

 

 

 

 

 

 

 

LED behavior for this indica-

The reader will beep once at current

Good Read Beep

A label has been successfully

tion is configurable via the

frequency, volume, mono/bi-tonal

scanned by the reader.

feature “Good Read: When

setting and duration upon a suc-

 

 

 

to Indicate

cessful label scan.

 

 

 

 

ROM Failure

There is an error in the reader's soft-

Flashes

Reader sounds one error beep at

ware/programming

highest volume.

 

 

 

 

 

 

Limited Scanning

Indicates that a host connection is

 

Reader 'chirps' six times at the high-

not established when the IBM or

N/A

Label Read

est frequency and current volume.

USB interface is enabled.

 

 

 

 

 

 

 

 

Reader Active

The reader is active and ready to

The LED is lit steadilya

N/A

Mode

scan.

 

 

 

 

 

 

Reader

The reader has been disabled by the

The LED blinks continuously

N/A

Disabled

host.

 

 

 

 

 

 

Green Spot is on

While in Stand Mode or Trigger

 

 

Stand Mode the green spot shall be

N/A

N/A

continuously

on while in stand watch state.

 

 

 

 

 

 

 

 

 

 

Upon successful read of a label, the

 

 

Green Spota flashes

software shall turn the green spot

N/A

N/A

momentarily

on for the time specified by the con-

 

 

 

figured value.

 

 

 

 

 

 

Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.

 

 

 

 

Label Program-

A valid programming label has been

LED blinks continuously

Reader sounds four low frequency

ming Mode Entry

scanned.

beeps.

 

 

 

 

 

Label Program-

 

 

Reader sounds three times at low-

ming Mode Rejec-

A label has been rejected.

N/A

est frequency & current volume.

tion of Label

 

 

 

 

 

 

 

 

 

Label Program-

In cases where multiple labels must

 

Reader sounds one short beep at

ming Mode Accep-

be scanned to program one feature,

 

N/A

highest frequency & current vol-

tance of Partial

this indication acknowledges each

 

ume.

Label

portion as it is successfully scanned.

 

 

 

 

 

 

 

Label Program-

Configuration option(s) have been

 

Reader sounds one high frequency

ming Mode Accep-

successfully programmed via labels

 

N/A

beep and 4 low frequency beeps

tance of

and the reader has exited Program-

 

followed by reset beeps.

Programming

ming Mode.

 

 

 

 

 

 

 

Label Program-

 

 

Reader sounds two times at low fre-

ming Mode Cancel

Cancel label has been scanned.

N/A

quency and current volume.

Item Entry

 

 

 

 

 

 

 

 

 

a. Except when in sleep mode or when a Good Read LED Duration other than 00 is selected

286

Gryphon™ I GD4100

Page 288
Image 288
Datalogic Scanning I GD4100 manual LED and Beeper Indications, Indication Description LED Beeper