Omron FQM1-MMP21 4-3Operating Modes, 4-3-2, Status and Operations in Each Operating Mode, Section

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 122
Image 122
Operating Modes

Operating Modes

Section 4-3

4-3 Operating Modes

4-3-1 Operating Modes

PROGRAM

MONITOR

RUN

Coordinator and Motion Control Modules have three operating modes that control the user program.

Programs are not executed and preparations, such as initializing the System Setup and other settings, transferring programs, checking programs, force- setting, force-resetting, and checking wiring can be executed prior to program execution. Motion Control Module built-in I/O refreshing and Coordinator Mod- ule cyclic refreshing are, however, executed in this mode.

Programs are executed, but some operations, such as online editing and changing present values in I/O memory, are enabled for trial operation and other adjustments.

Programs are executed but some operations, such as online editing and changing the present values in I/O memory using CX-Programmer, cannot be performed. The CX-Programmer can monitor the program execution status (program and I/O memory monitoring). The main system operation is per- formed in RUN mode.

Note (1) The operating mode of Motion Control Modules cannot be changed inde- pendently in Sync Mode. Always change the operating mode of the Co- ordinator Module in Sync Mode.

(2)To debug Motion Control Module programs, change the Coordinator Mod- ule to ASync Mode under the System Setup and change the operating mode for that Motion Control Module.

4-3-2

Status and Operations in Each Operating Mode

 

 

 

 

 

 

 

 

 

PROGRAM, RUN, and MONITOR are the three FQM1 operating modes. The

 

 

 

 

 

following tables list status and operations for each mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

Program

I/O

External

I/O Memory

 

 

 

 

CX-Programmer operations

 

 

 

 

 

execu-

refresh

outputs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tion

 

 

Cleared

Retained

I/O

Program

Program transfers

Program

System

Program

Force-

Chang-

Chang-

Chang-

 

(See

 

 

areas

areas

Memory

monitor-

 

 

check

Setup

changes

set/reset

ing timer/

ing timer/

ing I/O

 

note.)

 

 

 

 

monitor-

ing

FQM1 to

Com-

 

changes

 

 

counter

counter

Memory

 

 

 

 

 

 

ing

 

com-

puter to

 

 

 

 

SV

PV

PV

 

 

 

 

 

 

 

 

puter

FQM1

 

 

 

 

 

 

 

PROGRAM

Stopped

Exe-

OFF

Clear

Retained

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

 

 

cuted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN

Per-

Exe-

Con-

Controlled by pro-

OK

OK

OK

 

formed

cuted

trolled by

gram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

program

 

 

 

 

 

 

 

 

 

 

 

 

 

MONITOR

Per-

Exe-

Con-

Controlled by pro-

OK

OK

OK

OK

OK

OK

OK

OK

 

formed

cuted

trolled by

gram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

program

 

 

 

 

 

 

 

 

 

 

 

 

 

Note The following table shows the relationship of operating modes to tasks.

Mode

Cyclic task status

Interrupt task status

 

 

 

PROGRAM

Disabled

Stopped

 

 

 

RUN

Enabled

Executed if interrupt condition is

 

 

met.

MONITOR

 

 

 

 

 

 

99

Page 122
Image 122
Omron FQM1-MMP21 4-3Operating Modes, 4-3-2, Status and Operations in Each Operating Mode, Section, Program Monitor Run