System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

 

 

 

 

 

 

 

 

 

Address

Bits

Name

 

Function

 

Controlled by

A564

00

Analog Output 1

Conversion Enable

ON: Enables D/A conversion (enables analog output).

 

User

 

 

 

Bit

OFF: Disables DA conversion (analog values output

 

 

 

 

 

 

according to Output Stop Function specification in Sys-

 

 

 

 

 

 

tem Setup).

 

 

 

 

 

 

 

 

Note This bit is cleared when the Modules operating

 

 

 

 

 

 

mode is changed between RUN or MONITOR mode

 

 

 

 

 

 

and PROGRAM mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

01 to 15

Reserved

 

---

 

 

 

---

 

 

 

 

 

 

 

 

 

A565

00

Analog Output 2

Conversion Enable

ON: Enables D/A conversion (enables analog output).

 

User

 

 

 

Bit

OFF: Disables DA conversion (analog values output

 

 

 

 

 

 

according to Output Stop Function specification in Sys-

 

 

 

 

 

 

tem Setup).

 

 

 

 

 

 

 

 

Note This bit is cleared when the Modules operating

 

 

 

 

 

 

mode is changed between RUN or MONITOR mode

 

 

 

 

 

 

and PROGRAM mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

01 to 15

Reserved

 

---

 

 

 

---

 

 

 

 

 

 

 

 

 

A570

00

Adjustment Mode

Adjustment Enable

Analog Input

OFF: Adjustment disabled.

 

User

 

 

Command Bits

 

 

ON: Adjustment enabled.

 

 

 

01

 

Reserved

 

 

 

(Effective only

 

When one of these bits is turned ON,

 

 

 

 

 

 

 

 

 

02

 

Analog Out-

 

 

 

when A575 is

 

the default value (offset or gain value)

 

 

 

 

5A5A hex.)

 

put 1

corresponding to the selected I/O signal

 

 

 

03

 

 

Analog Out-

range is transferred to Adjustment

 

 

 

 

 

Mode Monitor Area (A572 and A573).

 

 

 

 

 

 

put 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

04 to 06

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07

 

Adjustment Mode

OFF: Offset adjustment

 

 

 

 

 

 

Specifier

ON: Gain adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

08 to 11

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

Adjustment Value

While this bit is ON, the offset or gain value will be

 

 

 

 

 

Increment

incremented by one resolution unit each 0.5 ms.

 

 

 

 

 

 

 

 

 

 

13

 

Adjustment Value

While this bit is ON, the offset or gain value will be dec-

 

 

 

 

 

Decrement

remented by one resolution unit each 0.5 ms.

 

 

 

 

 

 

 

 

 

 

14

 

Adjustment Value

OFF to ON: Clears the adjustment data to the factory

 

 

 

 

 

Clear

defaults.

 

 

 

 

 

15

 

Adjustment Value

OFF to ON: Reads the present value in the Adjustment

 

 

 

 

 

Set

Mode Monitor Area (A572 and A573) and saves this

 

 

 

 

 

 

value to flash memory. This adjustment value will be

 

 

 

 

 

 

used for the next normal mode operation.

 

 

 

 

 

 

 

 

 

A571

00

Adjustment Mode

Adjustment Opera-

ON when an operational error has been made, such as

 

Module

 

 

Status

tion Error

turning ON both the Analog Input and Analog Output 2

 

 

 

 

 

 

Adjustment Enable Bits at the same time.

 

 

 

 

 

 

 

 

 

 

 

 

01 to 14

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

Adjustment Mode

ON during adjustment mode operation (when A575

 

 

 

 

 

Started

contains 5A5A hex).

 

 

 

 

 

 

 

 

 

 

 

 

A572

00 to 15

Adjustment Mode

Both Analog Input

Setting Off-

The values in

10 to 10 V: FE0C to

 

Module/User

 

 

Monitor

and Analog Out-

set Monitor

these words

01F4 hex

 

 

 

 

(Effective only

puts

 

can be over-

• 0 to 10 V, 0 to 5 V, 1 to

 

 

 

 

when A575 is

 

 

written

5 V: FF38 to 00C8 hex

 

 

 

 

5A5A hex.)

 

 

directly, with-

 

 

 

A573

00 to 15

 

Gain Value

10 to 10 V: 1194 to

 

 

 

out using the

 

 

 

 

 

 

Monitor

157C hex

 

 

 

 

 

 

Adjustment

 

 

 

 

 

 

 

• 0 to 10 V, 0 to 5 V, 1 to

 

 

 

 

 

 

 

Value Incre-

 

 

 

 

 

 

 

ment/Decre-

5 V: 0ED8 to 1068 hex

 

 

 

 

 

 

 

ment Bits.

 

 

 

 

 

 

 

 

 

 

 

 

A574

00 to 15

 

Analog Inputs

Number of

Indicates the number of values to be

 

User

 

 

 

 

Average

averaged to obtain the Offset/Gain

 

 

 

 

 

 

Value Sam-

Value Monitor values in adjustment

 

 

 

 

 

 

ples in Adjust-

mode. The number of samples can be

 

 

 

 

 

 

ment Mode

set between 0000 and 0040 hex (0 to

 

 

 

 

 

 

 

64). Set this parameter before turning

 

 

 

 

 

 

 

ON the Adjustment Enable Bit.

 

 

A575

00 to 15

Adjustment Mode Password

5A5A hex: Adjustment mode enabled.

 

User

 

 

 

 

Other value: Adjustment mode disabled.

 

 

 

 

 

 

 

 

 

 

 

338