Omron FQM1-CM001 Pulse Inputs, 7-5-1, Applicable Models, 7-5-2, Outline, Specifications, 7-5-3

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 171
Image 171
Pulse InputsSection 7-5

Pulse InputsSection 7-5

7-5

Pulse Inputs

 

 

 

7-5-1

Applicable Models

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

Functions

 

 

 

 

 

 

 

 

 

FQM1-MMP21

 

Motion Control Module for Pulse I/O

 

 

 

 

 

 

 

 

 

FQM1-MMA21

 

Motion Control Module for Analog I/O

 

 

 

 

 

 

 

7-5-2

Outline

 

 

 

 

 

The FQM1-MMP21 and FQM1-MMA21 Motion Control Modules can receive

 

 

pulse inputs. The following table shows the processes that can be performed

 

 

by combining the pulse input function with the high-speed counters to count

 

 

pulse signals from a rotary encoder or other device and perform processing

 

 

based on the counter PV.

 

 

 

 

 

 

 

 

 

 

 

Process

Description

 

 

 

 

 

 

 

 

Target value comparison

An interrupt task is executed when the high-speed

 

 

 

interrupts

counter PV equals a preset target value.

 

 

 

 

 

 

 

 

Bit pattern outputs for

When the high-speed counter PV is within a specified

 

 

 

range comparisons

range, the user-set bit pattern specified in the compari-

 

 

 

 

 

 

son table is output internally.

 

 

 

 

 

 

 

 

Measurement

Movement in the high-speed counter or input pulse

 

 

 

modes 1 and 2

counting speed can be displayed while monitoring the

 

 

 

 

 

 

high-speed counter PV.

 

 

 

 

 

 

 

 

High-speed counter PV

High-speed counters 1 and 2 each have a latch register.

 

 

 

latch

 

 

Two latch inputs can be used to capture the high-speed

 

 

 

 

 

 

counter PVs at high speed.

 

 

 

 

 

 

 

Note Interrupts cannot be generated for range comparisons. Only bit patterns are output.

The high-speed counter PV movement during a fixed time interval (equivalent to the travel distance) and the high-speed counter’s frequency can also be monitored as required.

7-5-3

Specifications

 

 

 

 

 

 

 

 

 

 

Item

 

 

Specification

 

 

 

 

 

 

Number of counters

 

2

 

 

 

 

 

 

Pulse input operation mode

Phase differential

Increment/decrement

Pulse + direction

(Set in System Setup.)

 

 

 

 

 

 

 

 

 

 

Input pin

High-speed

High-speed

 

 

 

numbers

counter 1

counter 2

 

 

 

 

 

 

 

 

 

 

24 V: 1 (5)

24 V: 2 (6)

Phase A

Increment pulse

Pulse

 

LD: 3 (5)

LD: 4 (6)

 

 

 

 

 

 

 

 

 

 

24 V: 7 (11)

24 V: 8 (12)

Phase B

Decrement pulse

Direction pulse

 

LD: 9 (11)

LD: 10 (12)

 

 

 

 

 

 

 

 

 

 

24 V: 13 (17)

24 V: 14 (18)

Phase Z

Reset pulse

Reset pulse

 

LD: 15 (17)

LD: 16 (18)

 

 

 

 

 

 

 

 

 

Input method

 

Phase differential 1,

Single-phase 2

Single-phase + direc-

 

 

 

2, or 4 (switchable)

 

tion

 

 

 

 

 

 

 

 

 

Set in the System Setup.

 

 

 

 

 

(Set input for pulse input counter 1 and counter 2.)

 

 

 

Counting speed (Set separately for each

50 kHz (default) or 500 kHz (2 MHz when using phase differential 4)

port in the System Setup.)

 

 

 

 

 

 

 

Counter operation

 

Linear Counter or Circular Counter (Set in the System Setup.)

 

 

 

 

 

 

148

Page 171
Image 171
Omron FQM1-CM001, FQM1-MMA21 7-5-1, Applicable Models, 7-5-2, Outline, Specifications, 7-5-3, Pulse InputsSection