Auxiliary Area Allocations by Function

System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

Auxiliary Area Allocations by Function

The following tables list the words and bits allocated in the Auxiliary Area by function. These tables provide only an overview of the functionality. Refer to Appendix D Auxiliary Area Allocations for details or a list of allocations by address.

Motion Control Modules

Allocations That Are the Same for All Modules

Address

Bits

Name

Function

Controlled by

 

 

 

 

 

A202

00

Motion Control Module

ON if the Motion Control Module is in slot 1.

Module

 

 

slot 1

 

 

 

01

Motion Control Module

ON if the Motion Control Module is in slot 2.

 

 

 

slot 2

 

 

 

 

 

 

 

 

02

Motion Control Module

ON if the Motion Control Module is in slot 3.

 

 

 

slot 3

 

 

 

 

 

 

 

 

03

Motion Control Module

ON if the Motion Control Module is in slot 4.

 

 

 

slot 4

 

 

FQM1-MMP21 Motion Control Modules with Pulse I/O

Address

Bits

 

Name

 

Function

Controlled by

 

 

 

 

 

 

A600

00 to 15

High-speed Counter 1 PV

 

Range: 8000 0000 to 7FFF FFFF

Module

 

 

 

 

 

Note For a Linear Counter, high-speed counter over-

 

A601

00 to 15

 

 

 

 

 

 

 

 

 

flows/underflows are checked when the PV is read

 

A602

00 to 15

High-speed Counter 2 PV

 

 

 

(i.e., when Module internal I/O is refreshed).

 

A603

00 to 15

 

 

 

 

 

 

 

 

 

 

 

 

A604 to

00 to 15

High-

For following

PV of abso-

Contains the number of rotations data (PV) read from

 

A605

 

speed

counter modes

lute number

the Encoder when the SEN signal is input to the

 

 

 

Counter

• Absolute linear

of rotations

Servo Driver.

 

 

 

1

(CW)

 

8000 0000 to 7FFF FFFF hex

 

 

 

 

• Absolute circu-

 

 

 

 

 

 

lar

 

 

 

 

 

 

• Absolute linear

 

 

 

 

 

 

(CW+)

 

 

 

 

 

 

 

 

 

 

 

 

 

For following

Monitor data

• When monitoring counter movements (mode 1),

 

 

 

 

counter modes

 

contains the absolute value of the amount of

 

 

 

 

• Linear counter

 

change in the PV of the high-speed counter over

 

 

 

 

• Circular

 

the specified sampling time as a 8-digit hexadeci-

 

 

 

 

 

mal value (0000 0000 to FFFF FFFF hex).

 

 

 

 

counter

 

 

 

 

 

 

• When monitoring the counter frequency (mode 2),

 

 

 

 

 

 

 

 

 

 

 

 

contains the frequency of the high-speed counter

 

 

 

 

 

 

calculated from the PV of the high-speed counter

 

 

 

 

 

 

between 0 and 7A120 hex (0 and 500 kHz).

 

A606 to

00 to 15

High-

For following

PV of abso-

Same as for A604 and A605 for high-speed counter

 

A607

 

speed

counter modes

lute number

1 except that measuring the high-speed counter fre-

 

 

 

Counter

• Absolute linear

of rotations

quency is not possible for high-speed counter 2.

 

 

 

2

(CW)

 

 

 

 

 

 

• Absolute circu-

 

 

 

 

 

 

lar

 

 

 

 

 

 

• Absolute linear

 

 

 

 

 

 

(CW+)

 

 

 

 

 

 

 

 

 

 

 

 

 

For following

Monitor data

 

 

 

 

 

counter modes

 

 

 

 

 

 

• Linear counter

 

 

 

 

 

 

• Circular

 

 

 

 

 

 

counter

 

 

 

329