Cycle Time Settings

Cycle Time Settings

Section 5-6

Step 2: Turn ON Request Bit

Programming Example

Transferring DM Data from the Coordinator Module to a Motion Control Module: Turn ON the DM Write Request Bit (Coordinator Module to Motion Control Module) (A530.00).

Transferring DM Data from a Motion Control Module to the Coordinator Module: Turn ON the DM Read Request Bit (Motion Control Module to Coordinator Module) (A530.01).

The following diagram shows a programming example for the Coordinator Module when transferring DM data from the Coordinator Module (CM) to the Motion Control Module mounted to slot #1 (MM).

000.00

CM

D00200 to D00299

Transfer of 100 words of DM data

MM

D00100 to D00199

 

 

 

 

Set to slot #1, the slot for

 

 

@MOV

 

the Motion Control

 

#0001

 

Module for the DM data

 

 

A531

 

transfer.

 

 

 

 

 

 

 

@MOV

 

DM Transfer Size:

 

 

 

 

#0064

 

 

 

Set to 100 (64 hex).

 

 

A532

 

 

 

 

 

 

First DM Transfer

 

 

@MOV

 

 

 

 

Source Word (in CM):

 

 

#00C8

 

 

 

 

Set to C8 Hex (D00200).

 

 

A533

 

 

 

 

 

 

 

 

 

First DM Transfer

 

 

@MOV

 

Destination Word (in

 

#0064

 

 

 

MM):

 

 

A534

 

 

 

 

Set to 64 Hex (D00100).

 

 

 

 

 

 

 

A530.00 (CM to MM

 

 

 

 

 

 

transfer request)

Note When executing a DM data transfer from a Motion Control Module to the Coordinator Module (DM read request), do not set the First DM Transfer Source Word to D30000 or higher

5-6 Cycle Time Settings

This section describes the constant cycle time function, the watch cycle time function, and the cycle time monitoring function.

5-6-1 Constant Cycle Time Function

A constant cycle time can be set with the FQM1 Series. Programs are exe- cuted at standard intervals, which allows the control cycles for Servomotors to be constant.

The constant cycle time is set using the Cycle Time setting in the System

Setup (0.1 to 100.0 ms, unit: 0.1 ms).

Constant cycle

Constant cycle

Constant cycle

time (enabled)

time (enabled)

time (enabled)

Real cycle time

Real cycle time

Real cycle time

If the real cycle time is longer than the set cycle time, the constant cycle time function will be ignored and operation will be based on the real cycle time.