System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

 

 

 

 

 

 

Address

Bits

Name

Function

 

Controlled by

 

 

 

 

 

 

A524

00 to 15

Interrupt Counter 0

These words contain the interrupt counter PVs for interrupt input 0 to 3

 

Module

 

 

Counter PV

operating in counter mode.

 

 

A525

00 to 15

Interrupt Counter 1

The counter PV starts decrementing from the counter SV. When the

 

 

counter PV reaches the 0, the PV is automatically reset to the SV.

 

 

 

 

Counter PV

 

 

 

 

Range: 0000 to FFFF

 

 

 

 

 

 

 

A526

00 to 15

Interrupt Counter 2

 

 

 

 

 

 

 

Counter PV

 

 

 

 

 

 

 

 

 

A527

00 to 15

Interrupt Counter 3

 

 

 

 

 

Counter PV

 

 

 

Allocations That Are the Same for the Coordinator Module and Motion Control Modules

System Flags

Address

Bits

Name

 

 

 

 

Function

Controlled by

 

 

 

 

 

 

 

 

 

A000 to

00 to 15

Subroutine Input Condi-

These flags contain the status of the input condition for JSB(982) when

Module

A015

 

tion Flags

JSB(982) is used to call a subroutine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Address

 

Corresponding subroutines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Word

 

Bits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A000

 

00 to 15

 

SBN000 to SBN015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A001

 

00 to 15

 

SBN016 to SBN031

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A002

 

00 to 15

 

SBN032 to SBN047

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

to

 

to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A015

 

00 to 15

 

SBN240 to SBN255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A206 to

00 to 15

Maximum Cycle Time

These words store the maximum cycle time every cycle. The cycle

 

A207

 

 

time is recorded in 8-digit hexadecimal

 

 

 

 

(unit: 0.01 ms).

 

 

 

 

A208 to

00 to 15

Present Cycle Time

These words store the present cycle time every cycle in 8-digit hexa-

 

A209

 

 

decimal (unit: 0.01 ms).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program Error Flags

Address

Bits

Name

Function

Controlled by

 

 

 

 

 

A401

09

Program Error Flag

ON when program contents are incorrect.

Module

 

 

(fatal error)

Module operation will stop.

 

 

 

 

 

 

 

 

 

 

A405

11

No END Error Flag

ON when there isn’t an END(001) instruction in each program within a

 

 

 

 

task.

 

 

 

 

 

 

 

12

Task Error Flag

ON when a task error has occurred. The following conditions generate

 

 

 

 

a task error.

 

 

 

 

There isn’t a program allocated to the task.

 

 

 

 

 

 

 

13

Differentiation Overflow

The allowed value for Differentiation Flags which correspond to differ-

 

 

 

Error Flag

entiation instructions has been exceeded.

 

 

14

Illegal Instruction Error

ON when a program that cannot be executed has been stored.

 

 

 

Flag

 

 

 

 

 

 

 

 

15

UM Overflow Error Flag

ON when the last address in UM (User Memory) has been exceeded.

 

 

 

 

 

 

Other Error Flags and Bits

Error Log and Error Code

Address

Bits

Name

Function

Controlled by

 

 

 

 

 

A100 to

00 to 15

Error Log Area

When an error has occurred, the error code and error contents are

Module

A199

 

 

stored in the Error Log Area.

 

A408

00 to 15

Error Log Pointer

When an error occurs, the Error Log Pointer (binary) is incremented by

 

 

 

 

1 to indicate the location where the next error will be recorded as an

 

 

 

 

offset from the beginning of the Error Log Area (A100 to A199).

 