Omron FQM1-CM001 Pulse Outputs, Section, Pulse output, Description, Compatible instructions

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 195
Image 195
Pulse output

Pulse Outputs

 

 

Section 7-6

 

 

 

 

Pulse output

 

Description

Compatible instructions

operation mode

 

 

 

(Only in

 

 

 

Independent Mode)

 

 

 

 

 

 

(1)

Positions to a relative position from the present position.

PULS(886) + SPED(885) or

Relative pulse output

The number of output pulses (actual output amount) in

PULS(886) + ACC(888)

 

the specified direction is the target number of pulses.

(PULS(886) sets the number of pulses

 

• The frequency can be changed during pulse output.

and SPED(885) or ACC(888) starts the

 

pulse output.)

 

• The direction and the target number of pulses cannot

 

PLS2(887)

 

be changed during pulse output.

 

 

 

(Sets number of pulses and starts

 

 

 

pulse output.)

 

 

 

(2) (3)

Positions to an absolute position from the origin.

---

Absolute pulse out-

The number of output pulses is calculated automatically

 

put

from the difference between the present position (pulse

 

 

output PV) and target pulse amount.

 

 

Number of output pulses (actual output amount) =

 

 

Present position Target position

 

 

• The frequency can be changed during pulse output.

 

 

• The direction and the target number of pulses cannot

 

 

be changed during pulse output.

 

 

 

 

 

 

(2) Linear mode

Operates as linear counter with pulse

Same as for (1).

 

 

output values ranging from 8000 0000

 

 

 

to 7FFF FFFF hex.

 

 

 

 

 

 

(3) Circular

Operates as circular counter with pulse

PULS(886) + SPED(885) or

 

mode

output values ranging from 0000 0000

PULS(886) + ACC(888)

 

 

to the circular value.

(PULS(886) sets the number of pulses

 

 

When the pulse output PV exceeds the

and SPED(885) or ACC(888) starts the

 

 

pulse output.)

 

 

circular value, it is automatically

 

 

 

 

 

returned to 0000 0000. Conversely,

 

 

 

when the pulse output PV is decre-

 

 

 

mented from 0000 0000, it is automati-

 

 

 

cally returned to the circular value.

 

 

 

 

 

(4)

Positions to an absolute position from the origin.

PULS(886) (Sets the number of pulses

Electronic cam con-

The difference between the present position (pulse output

and starts the pulse output.)

trol (linear)

PV) and target pulse amount is calculated automatically.

ACC(888)

(5)

Number of output pulses (actual output quantity) =

PLS2(887)

Electronic cam con-

Present pulse position Target position

 

trol (circular)

• The direction is recognized automatically (CW direction

 

 

 

 

when the present position < target position, and CCW

 

 

direction when the present position > target position).

 

 

• The frequency and target position can be changed dur-

 

 

ing pulse output. The pulse output will stop if the direc-

 

 

tion is changed during pulse output.

 

 

 

 

 

172

Page 195
Image 195
Omron FQM1-CM001 Pulse Outputs, Section, Pulse output, Description, Compatible instructions, operation mode, Only in