Motion Control Modules

 

Section 2-4

 

FQM1-MMA21 (Analog I/O)

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

Specifications

 

 

 

 

 

 

 

 

 

 

 

I/O

Pulse inputs

 

Pulse inputs: 2 (compatible with Servo Drivers with absolute encoders)

 

40-pin

 

 

 

 

 

 

 

connector

 

 

 

Analog I/O

 

• Analog inputs: 1

 

 

 

 

 

 

 

 

 

 

 

 

(10 to 10 V, 0 to 10 V, 0 to 5 V, 1 to 5 V, and 4 to 20 mA),

 

 

 

 

 

 

 

conversion speed: 40 s/input

 

 

 

 

 

 

 

• Analog outputs: 2

 

 

 

 

 

 

 

(10 to 10 V, 0 to 10 V, 0 to 5 V, and 1 to 5 V), conversion speed: 40 s/output

 

 

 

 

 

 

 

 

 

 

 

 

General-purpose

 

General-purpose inputs: 12

 

26-pin

 

 

 

I/O

 

General-purpose outputs: 8

 

connector

 

 

 

 

 

 

 

 

 

Functions

Analog output

 

• Slope

 

 

 

 

 

 

 

• Output hold

 

 

 

 

 

 

 

• Offset/gain adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog input

 

• Offset/gain adjustment

 

 

 

 

 

 

 

 

 

 

Program

Program capacity

 

5 Ksteps

 

 

 

 

 

 

 

 

 

 

 

Nomenclature

Indicators

General-purpose I/O indicators

 

 

 

MMP21

 

RDY

 

A1

 

RUN

 

B1

 

ERR

 

A2

IN

OUT

 

B2

 

 

0

0

 

 

1

1

 

 

2

2

 

 

3

3

 

 

4

4

 

 

5

5

 

 

6

6

1

2

7

7

 

 

8

 

 

 

9

 

 

 

Pulse I/O indicators

 

 

 

 

MMP21

 

 

RDY

A1

 

 

RUN

B1

 

 

ERR

A2

 

 

 

 

B2

 

IN

 

OUT

 

 

 

26-pin connector

20general-purpose I/O points

 

10

 

 

 

 

11

 

 

 

26

 

 

 

 

25

 

 

 

 

 

 

CN2

 

 

CN1

 

 

2

 

1

39

40

 

 

 

 

 

40-pin connector Special I/O

 

0

0

 

 

1

1

 

 

 

 

2

2

 

 

 

 

3

3

 

 

 

 

4

4

 

 

 

 

5

5

 

 

 

 

6

6

 

 

 

 

7

7

 

 

 

 

8

 

 

 

 

 

 

9

 

 

 

 

 

 

10

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

1

2

Motion Control Module

Indicators

Indicator

Color

Name

Status

Meaning

 

 

 

 

 

RDY

Green

Module

Lit

Module operating normally.

 

 

operation

 

 

 

 

Not lit

Module error (e.g., WDT error)

 

 

 

 

 

 

 

 

RUN

Green

Program

Lit

Executing internal Module program

 

 

execution

 

 

 

 

Not lit

Internal Module program stopped.

 

 

 

 

 

 

 

 

ERR

Red

Module

Lit

Fatal error.

 

 

error

 

 

 

 

Flashing

Non-fatal error.

 

 

 

 

 

 

 

 

 

 

 

Not lit

Module operating normally.

 

 

 

 

 

IN0 to

Yellow

Inputs

Lit

Input signal ON

IN11

 

 

 

 

 

 

Not lit

Input signal OFF

 

 

 

 

 

 

 

 

0UT0 to

Yellow

Outputs

Lit

Output signal ON

OUT7

 

 

 

 

 

 

Not lit

Output signal OFF

 

 

 

 

 

 

 

 

A1/B1

Yellow

Pulse

Lit

Input signal ON

A2/B2

 

inputs

 

 

 

Not lit

Input signal OFF

 

 

 

 

 

 

 

 

Note IN0 to IN 11, OUT0 to OUT7, and A1 to B2 are all controlled by hardware.