Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 operation manual Appendix C, A626

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 358
Image 358
A626

System Setup, Auxiliary Area Allocations, and Built-in I/O Allocations

Appendix C

 

 

 

 

 

 

 

Address

Bits

Name

Function

 

Controlled

 

 

 

 

 

 

by

A626

00

Pulse Output 1

PV Reset Bit

OFF: Pulse output 1 PV not reset.

 

User

 

 

Command Bits

 

ON: Resets pulse output 1 PV.

 

 

 

 

 

 

 

 

 

01

 

Range Com-

OFF: Does not clear the execution results (A630) or output bit pat-

 

 

 

 

parison Results

tern (A631) from CTBL(882) execution for range comparison for

 

 

 

 

Clear Bit

the pulse output PV.

 

 

 

 

 

 

ON: Clears the execution results (A630) or output bit pattern

 

 

 

 

 

 

(A631) from CTBL(882) execution for range comparison for the

 

 

 

 

 

 

pulse output PV.

 

 

 

02 to 15

 

Reserved

---

 

 

 

 

 

 

 

 

 

A627

00

Pulse Output 2

PV Reset Bit

Same as for Pulse Output 1 Command Bits.

 

 

 

 

Command Bits

 

 

 

 

 

01

Range Com-

 

 

 

 

 

 

 

 

 

 

 

parison Results

 

 

 

 

 

 

Clear Bit

 

 

 

 

 

 

 

 

 

 

 

02 to 15

 

Reserved

 

 

 

 

 

 

 

 

 

 

A628

00 to 06

Pulse Output

Reserved

---

 

 

 

 

Control Bits

 

 

 

 

 

07

Speed Change

OFF: Sets the speed change cycle to 2 ms during pulse output for

 

 

(Apply to both

 

 

 

Cycle Bit

ACC(888) or PLS2(887).

 

 

 

 

pulse outputs 1

 

 

 

 

and 2.)

 

ON: Sets the speed change cycle to 1 ms during pulse output for

 

 

 

 

 

ACC(888) or PLS2(887).

 

 

 

08 to 13

 

Reserved

---

 

 

 

 

 

 

 

 

 

 

14

 

PLS2 Pulse

OFF: Sets Direction Priority Mode.

 

 

 

 

 

Output Direc-

In Direction Priority Mode, pulses are output only when the pulse

 

 

 

 

tion Priority

output direction and the direction of the specified absolute position

 

 

 

 

Mode Bit

are the same.

 

 

 

 

 

 

ON: Sets Absolute Position Priority Mode.

 

 

 

 

 

 

In Absolute Position Priority Mode, pulses are always output in the

 

 

 

 

 

direction of the specified absolute position.

 

 

 

 

 

 

 

 

 

 

15

 

Reserved

---

 

 

 

 

 

 

 

 

 

A629

00 to 15

Reserved

---

---

 

---

 

 

 

 

 

 

A630

00 to 15

Pulse Output 1

Range Com-

Contains the CTBL(882) execution results for range comparison.

Module

 

 

Monitor Data

parison Results

Bits 00 to 15 correspond to ranges 1 to 16.

 

 

 

 

 

 

OFF: No match

 

 

 

 

 

 

ON: Match

 

 

 

 

 

 

 

 

 

A631

00 to 15

 

Output Bit Pat-

Contains the output bit pattern when a match is found for

 

 

 

 

 

tern

CTBL(882) execution results for range comparison

 

 

 

 

 

 

Note If more than one match is found, an OR of the output bit pat-

 

 

 

 

 

terns with matches will be stored here.

 

 

 

 

 

 

 

 

 

A632

00 to 15

Pulse Output 2

Range Com-

Same as for Pulse Output 1 Monitor Data.

 

 

 

 

Monitor Data

parison Results

 

 

 

A633

00 to 15

 

Output Bit Pat-

 

 

 

 

 

 

tern

 

 

 

335

Page 358
Image 358
Omron FQM1-MMA21, FQM1-CM001, FQM1-MMP21 operation manual Appendix C, A626