System Setup (Coordinator Module)

Synchronous Data Refresh

 

Section 5-4

 

 

 

 

Synchronous Data

Word

Bits

Method for selecting type of synchronous data

Link Bit Areas in

address

 

 

Coordinator and

(See note

 

 

Motion Control

1.)

 

 

Modules

 

 

 

Sent from Motion

CIO 0216

00 to 15

Set using upper 2 words of Select Synchronous Data in the System

Control Module #4

 

 

Setup for Motion Control Module #4.

CIO 0217

00 to 15

 

 

 

 

 

 

 

CIO 0218

00 to 15

Set using lower 2 words of Select Synchronous Data in the System

 

 

 

Setup for Motion Control Module #4.

 

CIO 0219

00 to 15

 

 

 

 

 

 

 

Note

(1) Addresses are the same for the Coordinator Module and all Motion Con-

 

 

trol Modules.

(2) When the synchronous data is one-word data (analog input values, ana- log output values, built-in I/O, etc.), the other word can be used for gen- eral-purpose data.

5-4-4 Settings

System Setup (Coordinator Module)

The following settings must be made beforehand when using the synchronous data refresh function.

Synchronization between Modules and Sync Cycle Time must be set in the Coordinator Module's System Setup.

Synchronization between Modules

Name

Settings

Default

Description

Auxiliary Area

Enabled

 

 

 

 

Flags

 

 

 

 

 

 

 

Module Settings Tab Page

Sync/Async

Sync

Synchronization

---

At power ON

Sync Mode

 

 

between Modules

 

 

 

 

 

 

 

 

 

 

 

 

 

Sync Cycle Time

Name

Settings

Default

Description

Auxiliary Area

Enabled

 

 

 

 

Flags

 

 

 

 

 

 

 

Module Settings Tab Page

Default (cycle time)

CM cycle time

Sync cycle time

A404.06

At power ON

Sync Cycle Time

(0.1 to 10.0 ms)

 

(unit: 0.1 ms)

Sync Cycle Time

 

 

 

 

Too Long Flag

 

 

 

 

 

 

 

 

 

 

 

 

When the Sync Cycle Time is specified, all Motion Control Modules will syn- chronize with the Coordinator Module cycle time in PROGRAM mode. The specified Sync Cycle Time is enabled in RUN and MONITOR modes, and the Motion Control Module cycle times will change to the set Sync Cycle Time when in these modes.

Synchronous data link bits will be broadcast from each Module at the time specified under Sync Cycle Time.

If an interrupt task 000 is created, it can be used as a regular interrupt task executed each Sync Cycle Time.

When the Sync Cycle Time is on the default setting, the synchronous data link bits are broadcast from each Module each Coordinator Module cycle. The Motion Control Module cycles are synchronous with the Coordinator Module cycle.

Note If the Sync Cycle Time Too Long Flag (A404.06) turns ON in the Coordinator Module, it means that the Motion Control Module cycle time is longer than the Sync Cycle Time. Either change the Sync Cycle Time or check the Motion Control Module ladder program and shorten the Motion Control Module cycle time to less than the Sync Cycle Time.