Monitoring a High-speed Counter’s Frequency (Mode 2)

Pulse Inputs

Section 7-5

Note

Monitoring a High-speed Counter’s Frequency (Mode 2)

Note

High-speed Counter Movement (Mode 1) Specifications

Item

Specifications

 

 

Applicable pulse

Either pulse 1 (high-speed counter 1) or pulse 2 (high-speed

input

counter 2) can be used.

 

 

Displayable move-

0000 0000 to FFFF FFFF

ment

Note The software can generate the range of values shown

 

 

above, but some hardware may not be able to display

 

the full range due to input limitations.

 

 

Sampling time

Can be set to the cycle time or a fixed time between 1 and

 

9,999 ms.

 

 

Operating conditions

In the System Setup, set the pulse input’s counter data display

 

to counter movements (mode 1) and specify the sampling

 

time.

 

 

(1)When using mode 1 with a circular counter, set the maximum circular val- ue to 10 or higher.

(2)In mode 1, the Motion Control Module outputs the change as the differ- ence in the count measured each sampling period. The output change varies, so determine how to manage the output value in the user program when the counter is reset or the INI(880) instruction is executed to change the PV during sampling.

Mode 2 is supported by high-speed counter 1 only.

This function monitors the input pulse’s frequency from the high-speed counter movement value. The frequency is stored in A604 and A605. Status Flag A608.06 can be checked to determine whether or not the frequency is being measured.

(1)The frequency value stored in the Auxiliary Area is refreshed during the Motion Control Module’s I/O refreshing.

(2)The frequency measurement can be performed only with high-speed counter 1. The frequency cannot be measured with high-speed counter 2.

(3)When measurement is started, the measurement direction (A610.03) must be specified to match the direction of the input pulses being mea- sured.

Word

Bits

Function

Details

 

 

 

 

A604 and

00 to 15

High-speed Counter 1

Contains the frequency measure-

A605

 

Monitor Data

ment.

 

 

 

The frequency calculated from the

 

 

 

high-speed counter PV is stored in

 

 

 

8-digit hexadecimal (0000 0000 to

 

 

 

0007 A120 hex = 0 to 500 kHz).

 

 

 

 

A608

06

High-speed Counter 1

Measuring Flag

 

 

Status Flag

OFF: The high-speed counter fre-

 

 

 

 

 

 

quency measurement opera-

 

 

 

tion is stopped.

 

 

 

ON: The high-speed counter fre-

 

 

 

quency is being measured.

 

 

 

 

The pulse input’s counter data display must be set to frequency measurement (mode 2) in the System Setup in advance.

System Setup

Function

Details

 

 

 

Pulse Input Tab

Specifies the counter 1 mea-

2 hex: Frequency (mode 2)

Page

surement mode.

 

Counter data display

 

 

 

 

 

158