Omron FQM1-MMP21, FQM1-CM001, FQM1-MMA21 Pulse Inputs, Section, Latching a High-speedCounter’s PV

Models: FQM1-MMP21 FQM1-MMA21 FQM1-CM001

1 414
Download 414 pages 44.52 Kb
Page 182
Image 182
Latching a High-speed Counter’s PV

Pulse Inputs

Section 7-5

Latching a High-speed Counter’s PV

Frequency Measurement (Mode 2) Specifications

Item

Specifications

 

 

Applicable pulse

Only pulse 1 (high-speed counter 1) can be used.

input

 

 

 

Measurable frequen-

0 to 500 kHz

cies

Note When no pulses have been input for 10 s, the measured

 

 

value is set to 0 Hz (stopped). The previous output

 

value is retained during this 10-second interval.

 

 

Measurement period

5 ms max. (input frequency 500 Hz min.)

 

Note At input frequencies below 500 Hz, the measurement

 

period is increased to accommodate the lower input fre-

 

quencies and becomes 200 ms max. for input frequen-

 

cies of 10 Hz min.

 

 

Operating conditions

In the System Setup, set the pulse input’s counter data display

 

to frequency measurement (mode 2).

 

 

The present counter value can be latched at the rising edge of the latch signal input and stored as the latch register value. Each time the counter value is captured, the latch register value is overwritten with the new value and the old value is lost.

To use the latched counter value (latch register value) in the ladder program, read the latch register value with the PRV(881) instruction.

Word

Bit

Function

 

Details

 

 

 

 

A608

08

High-speed Counter 1

Count Latched Flag

 

 

Status Flag

Indicates that a high-speed counter

 

 

 

 

 

 

PV has been captured in the latch

 

 

 

register by the latch signal input.

 

 

 

 

A609

08

High-speed Counter 2

Count Latched Flag

 

 

Status Flag

(This flag has the same function as

 

 

 

 

 

 

the flag for high-speed counter 1.)

 

 

 

 

A610

08

High-speed Counter 1

Latch Input 1 Enable

 

 

Command

OFF: Disabled

 

 

 

 

 

 

ON:

Enabled

 

 

 

 

 

09

 

Latch Input 2 Enable

 

 

 

OFF: Disabled

 

 

 

ON:

Enabled

 

 

 

 

A611

08

High-speed Counter 2

Latch Input 1 Enable

 

 

Command

OFF: Disabled

 

 

 

 

 

 

ON:

Enabled

 

 

 

 

 

09

 

Latch Input 2 Enable

 

 

 

OFF: Disabled

 

 

 

ON:

Enabled

 

 

 

 

 

There is one latch register provided for each counter.

Both latch input 1 and latch input 2 can be enabled for a single counter, but only latch input 1 will be effective when both inputs are enabled.

Two latch inputs can be used for a single counter by enabling/disabling latch input 1 and 2 from the ladder program to enable only the desired input when it is required. In this case, allow at least one Motion Control Module cycle between the use of the two inputs.

159