Pulse Outputs

Section 7-6

Setting the

The speed change cycle for the ACC(888) and PLS2(887) instructions is

Speed-change Cycle

specified by setting the ON/OFF bit status of A628.07 before executing the

 

 

ACC(888) or PLS2(887) instruction.

2-ms Cycle

Execute ACC(888) or PLS2(887) with A628.07 OFF.

Execution condition

D00000

D00001

D00002

07D0

C350

0000

@ACC

#1

#0

D00000

Acceleration/deceleration rate: 2 kHz

Target speed: 50 kHz

1-ms Cycle

Execute ACC(888) or PLS2(887) with A628.07 ON.

P_On

Execution condition

D00000

D00001

D00002

07D0

C350

0000

A628.07

@ACC

#1

#0

D00000

Acceleration/deceleration rate: 2 kHz

Target speed: 50 kHz

7-6-12 PLS2(887) Pulse Output Direction Priority Mode

Pulse Output Direction Priority Mode

Absolute Position Priority Mode

The direction of pulses output by the PLS2(887) instruction can be deter- mined manually based on a user-set operand (pulse output direction priority mode) or automatically based on the absolute position (absolute position pri- ority mode).

The user determines the pulse output direction with an operand setting.

Pulses will be output only when the output direction specified in the PLS2(887) instruction matches the direction determined from the absolute position.

The pulse output direction is determined automatically from the absolute posi- tion.

The Motion Control Module ignores the pulse output direction specified by the PLS2(887) operand setting. This mode allows positioning to be based on the absolute position only, so it is not necessary for the user to specify the direc- tion.