REVERSING TIMER SPIN/DWELL ADJUSTMENTS
Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer.
Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).
TIMING LEGEND
SPIN TIME
Adjustment Position Number | 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
Time in Seconds* | 30 | 60 | 90 | 120 | 150 |
DWELL (STOP) TIME |
|
|
|
|
|
Adjustment Position Number | 1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
Time in Seconds* | 5 | 6.3 | 7.6 | 8.9 | 10.2 |
|
|
|
|
|
|
* Values shown are +/-
K. SHUTDOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2.Discontinue the gas supply and SHUT OFF external gas supply shutoff valve.
30 | Maytag Co. | 113394 - 8 |