American Dryer Corp MDG75PNH Reversing Timer SPIN/DWELL Adjustments, Shutdown Instructions

Models: MDG75MNV MDG75PNH

1 50
Download 50 pages 61.52 Kb
Page 34
Image 34

REVERSING TIMER SPIN/DWELL ADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer.

Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

SPIN TIME

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

30

60

90

120

150

DWELL (STOP) TIME

 

 

 

 

 

Adjustment Position Number

1

2

3

4

5

 

 

 

 

 

 

Time in Seconds*

5

6.3

7.6

8.9

10.2

 

 

 

 

 

 

* Values shown are +/- 1-second.

K. SHUTDOWN INSTRUCTIONS

If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:

1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2.Discontinue the gas supply and SHUT OFF external gas supply shutoff valve.

30

Maytag Co.

113394 - 8

Page 34
Image 34
American Dryer Corp MDG75PNH, MDG75MNV installation manual Reversing Timer SPIN/DWELL Adjustments, Shutdown Instructions