American Dryer Corp MDG75MNV, MDG75PNH installation manual Non-Reversing Gas

Models: MDG75MNV MDG75PNH

1 50
Download 50 pages 61.52 Kb
Page 23
Image 23

2.Electrical Service Specifications

NON-REVERSING (GAS)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes

to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

WIRE SIZE

BREAKER

 

 

 

60 Hz

50 Hz

 

Time Delay

 

120

2

13.0

*

20

20

208

2

7.6

*

15

15

220

2

7.3

8.6

*

15

15

230

2

8.0

*

15

15

240

2

7.0

*

15

15

208

3

4.7

*

15

15

230

3

4.7

*

15

15

240

3

4.9

*

15

15

380

3

2.9

*

15

15

380

4**

3.1

*

15

15

400

4**

3.2

*

15

15

416

4**

3.1

*

15

15

460/480

3

2.8

*

15

15

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.

 

10/13/08

** 3-Wire is available.

 

 

 

 

 

 

REVERSING (GAS)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes

to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

MINIMUM

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

WIRE SIZE

BREAKER

 

 

 

60 Hz

50 Hz

 

Time Delay

 

 

 

 

 

 

 

 

 

208

3

6.7

*

15

15

230

3

7.5

*

15

15

240

3

7.1

*

15

15

380

3

4.2

*

15

15

380

4**

4.3

*

15

15

400-416

4**

4.4

*

15

15

460/480

3

3.9

*

15

15

575

3

3.3

*

15

15

* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes.

 

10/13/08

** 3-Wire is available.

 

 

 

 

 

 

113394 - 8

Maytag Co.

19

Page 23
Image 23
American Dryer Corp MDG75MNV, MDG75PNH installation manual Non-Reversing Gas